Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(5)
AUX
(29)
BOSCH
(18)
BRYANT
(1)
Buderus
(5)
CARRIER
(25)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(92)
DE DIETRICH
(6)
EQUATION
(0)
FUJI ELECTRIC
(35)
FUJITSU
(83)
Fujitsu Atlantic
(42)
GENERAL
(44)
GREE
(33)
GSS
(1)
HAIER
(97)
HEC
(1)
HEIWA
(1)
HISENSE
(63)
HITACHI
(8)
IVT
(1)
Inventor
(24)
KAYSUN
(9)
LG
(67)
MIDEA
(140)
MITSUBISHI ELECTRIC
(87)
Mitsubishi Heavy Industries
(11)
NORD
(10)
Nobu
(2)
PANASONIC
(54)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(38)
THERMOR
(14)
TOSHIBA
(24)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(3)
XTRON
(1)
YORK
(7)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-36PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | 4.17 | -20° | 3.60 | 3.60 | |
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
AUW26U4RS8/ADT26UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.32 | -10° | 2.60 | 3.00 | |
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
AUW52U4RS7/ADT52UX4RGM8
Super Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.40 | 3.82 | -10° | 5.00 | 4.00 | |
|
AUW35U4RS8/ADT35UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.00 | -10° | 3.50 | 3.00 | |
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
AOEG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AUW40U4RS7/ADT40UX4RCL8
Turbo Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.11 | -10° | 4.10 | 4.00 | |
|
AUW52U4RS7/ADT52UX4RCL8
Super Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.79 | -10° | 5.00 | 4.00 | |
|
U-60PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.04 | -15° | 5.70 | 4.40 | |
|
PUZ-ZM50VKA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA2/PLA-M50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PLA-M50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
RZAG35A / FCAG35B
RZAG
|
DAIKIN | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -20° | 3.50 | 3.30 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
U-50PZ3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.94 | -15° | 4.70 | 4.00 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
SRC40ZSX-W1/FDTC40VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.37 | 3.98 | -20° | 4.00 | 4.00 | |
|
UUB1 U20 / UM18FH N10
UU
|
LG | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.89 | -10° | 5.00 | 4.40 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
UUB1 U20 / UT18FH NB0
UU
|
LG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.95 | -10° | 5.00 | 4.10 | |
|
PUZ-ZM60VHA2/PEAD-M60JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PEAD-M60JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PEAD-M60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PEAD-M60JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PLA-M60EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.76 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PLA-M60EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.76 | -20° | 6.10 | 4.40 | |
|
3MXM40A9 / CTXM15R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM40A9 / CTXM15A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
U-50PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.61 | -20° | 5.00 | 4.00 | |
|
RAC-50NPE / RAI-50RPE
RAC-NPE(D)
|
HITACHI | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.84 | 4.37 | 3.82 | -15° | 5.00 | 4.30 | |
|
RXM50A8 / FVXM50B
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.26 | 3.72 | -20° | 5.00 | 4.10 | |
|
RXM50R / FVXM50A9
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.81 | -15° | 5.00 | 4.10 | |
|
RZAG50A / FBA50A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.80 | -20° | 5.00 | 4.30 | |
|
CU-Z42YKEA / CS-Z42YKEA
2022
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
CU-Z42YKEA-1 / CS-Z42YKEA-1
2024
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
MXZ-2F53VFH4/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 4.10 | -20° | 5.30 | 3.50 | |
|
MXZ-2F53VFH5/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 4.10 | -20° | 5.30 | 3.50 | |
|
RZAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -10° | 3.50 | 3.30 | |
|
AOYG18KBTB/ARXG18KHTAP
ARY**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 |