Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(1)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(29)
EQUATION
(0)
FUJI ELECTRIC
(7)
FUJITSU
(21)
Fujitsu Atlantic
(10)
GENERAL
(8)
GREE
(0)
GSS
(0)
HAIER
(8)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(8)
MIDEA
(1)
MITSUBISHI ELECTRIC
(12)
Mitsubishi Heavy Industries
(1)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(1)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP561ATW-E/RAV-HM561BTP-E
SDI
|
TOSHIBA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.81 | 4.27 | 3.48 | -27° | 5.00 | 3.80 | |
|
PUZ-ZM60VHA2/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
CU-Z50UBEA / CS-Z50UD3EAW
2017
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
UUB1 U20 / CL24F N30
UU
|
LG | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.11 | -10° | 6.80 | 4.20 | |
|
SUZ-SM50VA/PEAD-SM50JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-SM50VA/PEAD-SM50JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-SM50VA2/PEAD-SM50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
UUB1 U20 / CM24F N10
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
UUB1 U20 / CM24F N11
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
RXM50R / FNA50A9
RXM
|
DAIKIN | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.77 | 4.09 | 3.34 | -15° | 5.00 | 4.00 | |
|
RXM50A / FNA50A9
RXM
|
DAIKIN | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.77 | 4.09 | 3.34 | -15° | 5.00 | 4.00 | |
|
RXM50A8 / FNA50A9
RXM
|
DAIKIN | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.05 | 3.22 | -15° | 5.00 | 4.00 | |
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
SUZ-M50VA/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RXM50A9 / FNA50A9
RXM
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.09 | 3.33 | -10° | 5.00 | 4.00 | |
|
SUZ-M50VA/SEZ-M50DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/SEZ-M50DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/SEZ-M50DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
RZAG50A / FDXM50F9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG50A / FNA50A9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
ARXM50R / ADEA50A
ARXM
|
DAIKIN | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.65 | 4.00 | 3.74 | -15° | 5.00 | 4.40 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOEG22KATA/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
SRC50ZSX-W3/FDUM50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.89 | 3.39 | -20° | 5.00 | 3.70 | |
|
RXM50R / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
RXM50A / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 |