Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(1)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(9)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(9)
Fujitsu Atlantic
(3)
GENERAL
(1)
GREE
(0)
GSS
(0)
HAIER
(6)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(4)
MIDEA
(0)
MITSUBISHI ELECTRIC
(7)
Mitsubishi Heavy Industries
(3)
NORD
(0)
Nobu
(0)
PANASONIC
(3)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(1)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 | |
|
U-50PZH3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.80 | 4.03 | -20° | 5.00 | 4.00 | |
|
U-36PZH3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.90 | 5.00 | -20° | 3.50 | 3.10 | |
|
RAV-GP561ATW-E/RAV-HM561CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.93 | 4.73 | 4.03 | -27° | 5.00 | 3.80 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
RZAG50B / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -10° | 5.00 | 4.00 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
UUB1 U20 / UV30F N10
UU
|
LG | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.23 | -10° | 7.50 | 4.40 | |
|
UUB1 U20 / UV18F N10
UU
|
LG | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.29 | -10° | 5.00 | 4.20 | |
|
AC50S2SG2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
YDAM-050R-09M25/FDHM-050N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
PUZ-ZM50VKA2/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 4.04 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 4.04 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM60VHA2/PCA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.01 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PCA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.01 | -20° | 6.10 | 4.40 | |
|
UUB1 U20 / UV24F N10
UU
|
LG | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.28 | -10° | 6.80 | 4.30 | |
|
RXM35R9 / FHA35A9
RXM
|
DAIKIN | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.43 | 4.08 | -15° | 3.40 | 3.10 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
SRC40ZSX-W1/FDE40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.02 | 4.09 | -20° | 4.00 | 3.00 | |
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AOYG18KBTB/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ABHG18KRTA
ABH**K
|
GENERAL | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG18KBTB/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ABYG18KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
RZAG35B / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -10° | 3.50 | 3.10 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 | |
|
SUZ-M50VA/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
SC250HIDS8/AIC250HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42QZL018D8S*/38QUS018D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
ROG18KATA/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 |