Filters · 3 active
Manufacturer:
CARRIER
YORK
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 | |
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 | |
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 | |
|
42QCE021D8SH/38QCE021D8SH
Wall mounted
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
38WHSH060A1A0TEE/40WHHW060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHB060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
38QUS018D8S2-2/42QSS009D8S*
Ducted
|
CARRIER | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
42QHE24D8SH*/38QHE24D8SH*
Wall mounted
|
CARRIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
38WHSM071A1A0TEE/40WHMW071D1A0TEE
40WHM
|
CARRIER | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.20 | -20° | 8.10 | 5.49 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
42QSS024D8S*/38QUS024D8S*
Ducted
|
CARRIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
YUKF24BYEEBMO-1/YEKF24BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
38QUS018D8S2-2/42QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.56 | 4.00 | 4.29 | -10° | 5.79 | 4.50 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
42QHG024D8S*/38QHG024D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
42QHG022D8S*/38QHG022D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.74 | -10° | 6.25 | 4.90 | |
|
38QUS018D8S2-2/42QTD009D8S*
Cassette
|
CARRIER | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
YHKF24YEEBMJO-X/YHKF24XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24YEEBMJO-T/YHKF24XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24XEEBMH-RY / YHKF24YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.90 | 3.40 | -10° | 7.20 | 4.90 |