Filters · 3 active
Manufacturer:
FUJITSU
Inventor
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEG18KBCA3/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
AOYG22KBTB/AUXG22KRLB
AUY**K
|
FUJITSU | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/AUXG22KRLB
AUXG**K
|
FUJITSU | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOEH18KMTG/ASEH18KMTGL
ASE**K
|
FUJITSU | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
EMPVO-24/EMPVI-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
EMPVO(W)-24/EMPVI(W)-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
AOYG22KBTB/ARXG22KHTAP
ARY**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KHTAP
ARXG**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
EQO-24/EQI-24WFI
Econ IQ
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
INVBO-24/INVBI-24WFI
Intellia
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
AOYG18KMTA/ASYG18KMTE
ASY**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOEG18KMTA/ASEG18KMTE
ASE**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
EMPVO-18/EMPVI-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
EMPVO(W)-18/EMPVI(W)-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
INVO-24/INVI-24WFI
Intellia
|
Inventor | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AOYG22KBTB/AUXG22KVLA
AUY**K
|
FUJITSU | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.74 | -15° | 6.00 | 4.80 | |
|
MFVO32-18/MFVI32-18WFI
Comfort
|
Inventor | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
LEUVO-24/LEUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LHUVO-24/LHUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVOCP -24/LEUVICP-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOEG18KLCA/ASEG18KLCA
ASE**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLA
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLB
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOEG24KBCA3/ASEH12KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MFVO32-24/MFVI32-24WFI
Comfort
|
Inventor | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
NRO-24/NRI-24WFI
Nura
|
Inventor | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
U6RSL(3)-21/LV6iCI-09WiFiR+LV6iCI-12WiFiR
ODU + Cassette
|
Inventor | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
Ν2UVO-24/Ν2UVI-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
N2VOCP-24/Ν2VICP-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
NPVO-24/NPVI-24WFI
Neo Plus
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 |