Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(3)
AUX
(0)
BOSCH
(4)
BRYANT
(1)
Buderus
(2)
CARRIER
(5)
CIAT
(2)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(28)
EQUATION
(1)
FUJI ELECTRIC
(2)
FUJITSU
(3)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(4)
GSS
(0)
HAIER
(39)
HEC
(0)
HEIWA
(1)
HISENSE
(31)
HITACHI
(4)
IVT
(0)
Inventor
(10)
KAYSUN
(1)
LG
(45)
MIDEA
(56)
MITSUBISHI ELECTRIC
(26)
Mitsubishi Heavy Industries
(1)
NORD
(7)
Nobu
(2)
PANASONIC
(4)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(14)
THERMOR
(2)
TOSHIBA
(14)
Viessmann
(1)
Vulcano
(2)
WESTPOINT
(0)
YORK
(3)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP801ATW-E/RAV-HM801FT-E
SDI
|
TOSHIBA | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.43 | 3.38 | -27° | 7.10 | 5.10 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
UUC1 U40 / UT30F NB0
U4
|
LG | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.40 | -10° | 8.00 | 5.60 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
AD71S2SM3FA/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.06 | 4.47 | 3.34 | -10° | 6.80 | 5.00 | |
|
AC71S2SG2FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.25 | 3.26 | -10° | 7.10 | 5.00 | |
|
RZAG60B / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -10° | 6.00 | 4.60 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
RZAG60A / FCAG60B
RZAG
|
DAIKIN | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -20° | 6.00 | 4.60 | |
|
AOHG18KLTA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLTA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHG18KLCA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLCA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOEG18KLCA/ASEG18KLCA
ASE**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AUW71U4RJ7/ADT71UX4RCL8
Super Inverter R32
|
HISENSE | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -10° | 7.00 | 5.50 | |
|
RAS-24E2AVG-E/RAS-B24S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
RAS-24E2AVG-E/RAS-B24E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
RAS-24CAVG-E/RAS-B24CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
38WHSM071A1A0TEE/40WHMW071D1A0TEE
40WHM
|
CARRIER | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
MUZ-HR71VF/MSZ-HR71VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -10° | 7.10 | 5.40 | |
|
MUZ-HR71VF2/MSZ-HR71VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -10° | 7.10 | 5.40 | |
|
CU-Z60CBEA / CS-Z60CD3EAW
2025
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
RXM60R / FCAG60B
RXM
|
DAIKIN | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.38 | -15° | 5.70 | 4.71 | |
|
SRC60ZSX-W3/FDTC60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.10 | 3.13 | -20° | 5.60 | 5.10 | |
|
RZAG60B / FCAG60B
RZAG
|
DAIKIN | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -10° | 6.00 | 4.60 | |
|
AB71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.08 | 4.47 | 3.30 | -10° | 7.10 | 5.00 | |
|
AB71S2SR1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.08 | 4.47 | 3.30 | -10° | 7.10 | 5.00 | |
|
RXM60R / FNA60A9
RXM
|
DAIKIN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.56 | 4.16 | 3.11 | -15° | 6.00 | 4.60 | |
|
Z4UW30GFA3 / ZMNW07GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.01 | 3.50 | -10° | 7.70 | 5.90 | |
|
S24EQ U24 / S24EQ NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S3UW24K23BA / S3NW24K23BA
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24ET U24 / S24ET NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BH U24 / AC24BH NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
DC24RK U24 / DC24RK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BK U24 / AC24BK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SK U24 / PC24SK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 |