Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(15)
ATLANTIC
(6)
AUX
(16)
BOSCH
(13)
BRYANT
(1)
Buderus
(8)
CARRIER
(9)
CIAT
(5)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(50)
EQUATION
(2)
FUJI ELECTRIC
(7)
FUJITSU
(18)
Fujitsu Atlantic
(8)
GENERAL
(7)
GREE
(7)
GSS
(1)
HAIER
(97)
HEC
(0)
HEIWA
(1)
HISENSE
(30)
HITACHI
(10)
IVT
(0)
Inventor
(16)
KAYSUN
(4)
LG
(16)
MIDEA
(78)
MITSUBISHI ELECTRIC
(27)
Mitsubishi Heavy Industries
(2)
NORD
(6)
Nobu
(2)
PANASONIC
(7)
RIELLO
(5)
Rotenso
(0)
SAMSUNG
(14)
THERMOR
(15)
TOSHIBA
(5)
Viessmann
(1)
Vulcano
(6)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
AP71DFMHRA/1U71WEMFRA
New Cabinet RAC
|
HAIER | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
5MWXM90A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.00 | 3.89 | -15° | 6.80 | 4.60 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
PUZ-ZM71VHA2/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.80 | |
|
AD71S2SM9FA(H)/1U71S2SR3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.00 | 3.80 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/DDHM-070N-09M22
OASIS
|
AIRWELL | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.00 | 3.80 | -10° | 7.10 | 5.00 | |
|
UUC1 U40 / CM24F N10
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40TK / ZBNW24GM1A1
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F N11
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
AL-H18/4DR3HB3(U) / AUMD-H18/4DR3HB2
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
RXYL52M-T1B/FDMD52M-B
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
AC71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.00 | 3.52 | -10° | 7.10 | 5.00 | |
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
MOX430U-24HFN8-QRD0W(GA)/MTI-24HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
MOX430U-24HFN8-Q(GA)/MTI-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
42QSS024D8S*/38QUS024D8S*
Ducted
|
CARRIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
DC270HIDS8/AIC270HIDS8
Ducted
|
RIELLO | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
MOX430U-24HFN8-QRD0W(GA)/MTI-24HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
MO-24N8-Q/MTI-24HNX
Duct R32
|
MIDEA | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPD-71 DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPD-71V DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
MOX430U-24HFN8-QRD0W(GA)-GR/MTI-24HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
YUKF24BYEEBMO-1/YEKF24BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
AL-H18/4DR3HB3(U) / AUCF-H18/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
RXYL52M-T1B/FDCF52F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
3MXM52A9 / FDXM25F9 / FDXM25F9
3MXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FDXM25F9 / FDXM25F9
4MWXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ABHG22KRTA
ABH**K
|
GENERAL | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 |