Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(5)
ATLANTIC
(1)
AUX
(4)
BOSCH
(2)
BRYANT
(0)
Buderus
(1)
CARRIER
(2)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(13)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(6)
Fujitsu Atlantic
(2)
GENERAL
(1)
GREE
(0)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(2)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(5)
MIDEA
(3)
MITSUBISHI ELECTRIC
(9)
Mitsubishi Heavy Industries
(3)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(3)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP801ATW-E/RAV-HM801CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 100 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 8.35 | 5.10 | 4.44 | -27° | 7.10 | 5.10 | |
|
U-60PZH3E5 / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.80 | 4.14 | -20° | 6.00 | 4.60 | |
|
U-71PZH4E5 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
U-71PZH4E8 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
U-60PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.60 | 4.11 | -15° | 6.00 | 4.60 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
UUC1 U40 / UV24FH N20
U4
|
LG | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.11 | -10° | 6.80 | 5.40 | |
|
RAV-GM802ATW-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.48 | 3.87 | -15° | 6.90 | 5.10 | |
|
RZAG71NV1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
FDC90VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.78 | 4.46 | 4.52 | -15° | 9.00 | 5.80 | |
|
SRC60ZSX-W3/FDE60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.72 | 4.41 | 3.60 | -20° | 5.60 | 4.50 | |
|
UUC1 U40 / UV30FH N20
U4
|
LG | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -10° | 8.00 | 5.40 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
RZAG71NV1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
PUZ-ZM71VHA2/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RZAG71NV1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
AUW60U4RJ7/AVT60UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.80 | -10° | 6.20 | 5.50 | |
|
AC71S2SG2FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.25 | 3.26 | -10° | 7.10 | 5.00 | |
|
RZAG60B / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -10° | 6.00 | 4.60 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
AC71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.20 | 3.52 | -10° | 7.10 | 5.00 | |
|
AUW71U4RJ7/AVT71UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -10° | 7.00 | 5.50 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
SUZ-M71VA/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 5.80 | |
|
PUZ-M71VHA/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 4.70 | |
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
Vitoclima100-SIFCAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ceiling suspended
|
Viessmann | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
SUZ-M60VA/PCA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.00 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/PCA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.00 | -10° | 6.10 | 4.60 | |
|
RAV-GM801ATP-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.21 | 3.62 | -15° | 6.90 | 5.10 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 |