Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(46)
BOSCH
(26)
BRYANT
(1)
Buderus
(12)
CARRIER
(28)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
DE DIETRICH
(3)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(27)
GSS
(1)
HAIER
(141)
HEC
(0)
HEIWA
(2)
HISENSE
(94)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(8)
LG
(73)
MIDEA
(158)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
PITSOS
(1)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(6)
XTRON
(1)
YORK
(5)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS71S2SF1FA-MW3/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71WEGFRA
RAC Flexis
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
U-71PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.40 | 4.10 | -15° | 6.90 | 5.20 | |
|
RAV-GM801ATP-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.20 | 4.13 | 3.32 | -15° | 6.70 | 5.10 | |
|
5MWXM90A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.00 | 3.89 | -15° | 6.80 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
RZASG71MV1 / FBA71A9
RZASG
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.01 | -10° | 6.80 | 4.50 | ||
|
FDC71VNP-W/FDU71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.12 | 3.76 | -15° | 7.10 | 5.70 | |
|
FDC71VNP-W/FDUM71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.12 | 3.76 | -15° | 7.10 | 5.70 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RZAG71NV1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
U-71PZ3E5A / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.40 | 4.23 | -15° | 7.10 | 5.20 | |
|
RAS-5M34G3AVG-E1/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
RAS-5M34G3AVG-E1/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
PUZ-ZM71VHA2/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.80 | |
|
ASW-H24G3A4/MAR3DI-B9 / ASW-H24G3A4/MAR3DI-B9
M SERIES
|
AUX | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.20 | 3.04 | -10° | 6.70 | 5.30 | |
|
ASW-H24G3A4/CAR3DI-B9 / ASW-H24G3A4/CAR3DI-B9
C SERIES
|
AUX | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.20 | 3.04 | -10° | 6.70 | 5.30 | |
|
ASW-H24G3B4/MAR3DI-B9 / ASW-H24G3B4/MAR3DI-B9
M SERIES
|
AUX | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.20 | 3.04 | -10° | 6.70 | 5.30 | |
|
MX4-22RD1-EF/EF-22RD1
Solunar
|
MIDEA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.71 | -10° | 6.10 | 4.80 | |
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
AD71S2SM9FA(H)/1U71S2SR3FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.00 | 3.80 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/DDHM-070N-09M22
OASIS
|
AIRWELL | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.00 | 3.80 | -10° | 7.10 | 5.00 | |
|
UUC1 U40 / CM24F N10
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40TK / ZBNW24GM1A1
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F N11
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
GWH24YEXF-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.90 | -10° | 7.10 | 5.60 | |
|
S24EC U24 / S24EC NSK
U24A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SC U24 / PC24SC NSK
U24A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
CU-Z60UBEA / CS-Z60UD3EAW
2017
|
PANASONIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
RXP60N / FTXP60N
RXP
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 4.10 | 3.63 | -15° | 6.00 | 4.80 | |
|
RXP60N9 / FTXP60N
RXP
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 4.10 | 3.63 | -15° | 6.00 | 4.80 | |
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
RAC-DJ60WHAE / RAK-DJ60RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.50 | -15° | 6.00 | 4.80 | |
|
MU4R27 U24A0 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.19 | 3.50 | -10° | 7.00 | 5.50 | |
|
AL-H18/4DR3HB3(U) / AUMD-H18/4DR3HB2
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
RXYL52M-T1B/FDMD52M-B
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
AC71S2SG1FA/1U71S2ST1FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.00 | 3.52 | -10° | 7.10 | 5.00 | |
|
RXM60R / FBA60A9
RXM
|
DAIKIN | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.91 | 4.01 | 3.71 | -15° | 5.70 | 4.60 | |
|
CU-Z71YKEA / CS-Z71YKEA
2022
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -15° | 7.10 | 5.50 |