Filters · 4 active
Manufacturer:
AIRCLASS
HAIER
SAMSUNG
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
AD105S2SM3FA(H)/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.50 | -10° | 9.50 | 7.20 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
3U63S2LD1FA/AS35PBPHRA-PRE+AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.20 | 4.40 | -10° | 6.30 | 6.60 | |
|
AP105S2SK1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.60 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AD125S2SM9FA(H)/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
AD125S2SM9FA(H)/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
2U70S2SR1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
2U70S2LD1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
AS105PFAHRA/1U105XEAFRA
HAIER - QUARTZ
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AS105PFAHRA/1U105XEAFRA-H
Wall mounted - Quartz
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AD105S2SM3FA/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM3FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM9FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
AC105S2SH2FA(H)/1U105S2SQ1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
AD105S2SM9FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
AD105S2SM9FA(H)/1U105S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.50 | 7.20 | |
|
ADH125H1ERG/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.43 | 12.40 | 8.00 | ||
|
4U105S2LS1FA/AS50PDPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 10.50 | 7.50 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AD90S2SM3FA(H)/ 1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.65 | -10° | 8.50 | 7.00 | |
|
AD90S2SM9FA(H)/1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
AC105S2SH1FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
ADH125H1ERG/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.40 | 12.30 | 8.00 | ||
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AD125S2SM3FA/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.54 | -10° | 12.10 | 8.00 | |
|
AD125S2SM3FA/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.57 | -10° | 12.10 | 8.00 | |
|
ADH125H1ERG/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.97 | 3.43 | 12.40 | 8.00 | ||
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
AD125S2SM8FA/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 |