Filters · 4 active
Manufacturer:
COLIBRI
HAIER
Inventor
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U7iRS-30/V7iDI-30WiFiR
Ducted R32
|
Inventor | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
AD105S2SM3FA(H)/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.50 | -10° | 9.50 | 7.20 | |
|
U7RS-36/V7iDI-36WiFiR
Ducted R32
|
Inventor | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
3U63S2LD1FA/AS35PBPHRA-PRE+AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.20 | 4.40 | -10° | 6.30 | 6.60 | |
|
AP105S2SK1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.60 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AD125S2SM9FA(H)/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
AD125S2SM9FA(H)/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
2U70S2SR1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
2U70S2LD1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
AS105PFAHRA/1U105XEAFRA
HAIER - QUARTZ
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AS105PFAHRA/1U105XEAFRA-H
Wall mounted - Quartz
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AD105S2SM3FA/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM3FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM9FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
AC105S2SH2FA(H)/1U105S2SQ1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
AD105S2SM9FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
AD105S2SM9FA(H)/1U105S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.50 | 7.20 | |
|
ADH125H1ERG/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.43 | 12.40 | 8.00 | ||
|
4U105S2LS1FA/AS50PDPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 10.50 | 7.50 | |
|
AD90S2SM3FA(H)/ 1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.65 | -10° | 8.50 | 7.00 | |
|
AD90S2SM9FA(H)/1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
AC105S2SH1FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
ADH125H1ERG/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.40 | 12.30 | 8.00 | ||
|
AD125S2SM3FA/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.54 | -10° | 12.10 | 8.00 | |
|
AD125S2SM3FA/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.57 | -10° | 12.10 | 8.00 | |
|
ADH125H1ERG/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.97 | 3.43 | 12.40 | 8.00 | ||
|
AD125S2SM8FA/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 | ||
|
AD125S2SM8FA(H)/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 | ||
|
AD125S2SM9FA(H)/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 | ||
|
U7iRS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
AC105S2SH1FA/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 4.00 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC125S2SK2FA(H)/1U125S2SN3FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
AC125S2SK2FA(H)/1U125S2SN3FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AD125S2SM3FA/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 | ||
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
ADH125H1ERG/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.94 | 3.40 | 12.30 | 8.00 | ||
|
3U80S2LR1FA/AS35PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 8.00 | 6.00 | |
|
4U85S2LR1FA/AS35PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 8.50 | 6.00 | |
|
AD125S2SM8FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
AD125S2SM8FA(H)/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
AD125S2SM9FA(H)/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 |