Filters · 3 active
Manufacturer:
Mitsubishi Heavy Industries
SAMSUNG
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
FDC90VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.56 | 4.74 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
FDC100VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.53 | 4.29 | -15° | 10.00 | 6.40 | |
|
SRC71ZR-W/SRK71ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -15° | 7.10 | 6.60 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDTC40VH/FDTC40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.37 | -20° | 7.10 | 6.00 | |
|
SRC80ZR-W/SRK80ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -15° | 8.00 | 7.10 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
FDC90VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
SRC71ZR-W/SRK71ZR-WF
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -10° | 7.10 | 6.60 | |
|
FDC100VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.24 | 4.24 | -15° | 10.00 | 6.00 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
FDC71VNX-W/FDUM40VH/FDUM40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.15 | 4.44 | -20° | 7.10 | 6.00 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
SRC80ZR-W/SRK80ZR-WF
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -10° | 8.00 | 7.10 | |
|
SCM80ZS-W/SRK35ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | 4.77 | -15° | 8.00 | 6.70 | |
|
SRC71ZTL-W/SRK71ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.38 | -10° | 7.10 | 6.20 | |
|
FDC71VNX-W/FDF71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDF71VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
SCM71ZS-W/SRK20ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.91 | -10° | 7.10 | 6.70 | |
|
FDC100VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
SCM100ZS-W/SRK50ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 4.00 | -10° | 10.00 | 6.80 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
FDC125VNP-W/FDT125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.27 | 3.78 | 12.10 | 8.00 | ||
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
FDC100VNP-W/SRK100ZR-W
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.14 | 3.57 | -15° | 9.60 | 6.00 | |
|
FDC100VNP-W/SRK100ZR-WF
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.14 | 3.57 | -15° | 9.60 | 6.00 | |
|
FDC125VNP-W/FDU125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.01 | 3.69 | 12.10 | 7.90 | ||
|
FDC125VNP-W/FDUM125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.01 | 3.69 | 12.10 | 7.90 |