Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(0)
BOSCH
(1)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(6)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(14)
Fujitsu Atlantic
(6)
GENERAL
(7)
GREE
(1)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(0)
Inventor
(1)
KAYSUN
(1)
LG
(1)
MIDEA
(3)
MITSUBISHI ELECTRIC
(19)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(6)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-RZ50VUHZ/MSZ-RZ50VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -30° | 5.00 | 6.00 | |
|
AOEG24KBCA3/ASEH07KMCG/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTA3/ASHH07KMCG/ASHH09KMCG/ASHH09KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B50G3KVSG-ND
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 3.74 | -25° | 6.00 | 6.50 | |
|
MUZ-RW50VGHZ / MSZ-RW50VG
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
MUZ-RW50VGHZ2/MSZ-RW50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
MUZ-LN50VGHZ2/MSZ-LN50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
MUZ-LN50VGHZ3/MSZ-LN50VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
MUZ-LN60VG2/MSZ-LN60VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
MUZ-LN60VG3/MSZ-LN60VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B35S4KVPG-ND
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 3.74 | -25° | 6.00 | 6.50 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
RCI-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.73 | 4.33 | 4.07 | -15° | 7.00 | 6.00 | |
|
AOEG24KBTB/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
MUZ-FH50VEHZ/MSZ-FH50VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 4.05 | -25° | 5.00 | 6.00 | |
|
MXZ-4F72VF4/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
MXZ-4F72VF5/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG2/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
AOYG24KBTB/ARXG24KHTAP
ARY**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXG24KHTAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RDG24KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ARXG24KHTAP
ARXG**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXG24KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
3U63S2LD1FA/AS35PBPHRA-PRE+AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.20 | 4.40 | -10° | 6.30 | 6.60 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/AUXG24KRLB
AUXG**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXG24KMLA
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXG24KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RDG24KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXG24KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
AOYG24KBTB/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ABHG24KRTA
ABH**K
|
GENERAL | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
2U70S2SR1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 |