Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(3)
AUX
(12)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(5)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(186)
EQUATION
(0)
FUJI ELECTRIC
(8)
FUJITSU
(22)
Fujitsu Atlantic
(9)
GENERAL
(12)
GREE
(12)
GSS
(0)
HAIER
(37)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(17)
IVT
(0)
Inventor
(2)
KAYSUN
(2)
LG
(4)
MIDEA
(22)
MITSUBISHI ELECTRIC
(29)
Mitsubishi Heavy Industries
(27)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(10)
THERMOR
(2)
TOSHIBA
(17)
Viessmann
(1)
Vulcano
(1)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD85ZD1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | -10° | 8.50 | 6.00 | ||
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
AOEG36KBTA5/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
MUZ-RZ50VUHZ/MSZ-RZ50VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -30° | 5.00 | 6.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
AOEG30KBTA4/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOHG30KBTA4/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOEG24KBCA3/ASEH07KMCG/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTA3/ASHH07KMCG/ASHH09KMCG/ASHH09KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B50G3KVSG-ND
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 3.74 | -25° | 6.00 | 6.50 | |
|
MUZ-RW50VGHZ / MSZ-RW50VG
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
MUZ-RW50VGHZ2/MSZ-RW50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
MOX430UL-24HFN8-QRD0W/MFYC400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.30 | 3.70 | -10° | 7.10 | 6.10 | |
|
RAV-GM902ATW-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 4.12 | -15° | 8.00 | 6.30 | |
|
MUZ-LN50VGHZ2/MSZ-LN50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
MUZ-LN50VGHZ3/MSZ-LN50VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 4.65 | 4.65 | 12.10 | 6.00 | ||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 4.65 | 4.65 | 12.10 | 6.00 | ||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 4.65 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 4.65 | 12.10 | 6.00 | |||
|
RAV-GM901ATP-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -15° | 8.00 | 6.30 | |
|
5MWXM90A9 / FBA100A
5MWXM
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.22 | 4.21 | -15° | 8.70 | 6.46 | |
|
FDC90VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.56 | 4.74 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
MUZ-LN60VG2/MSZ-LN60VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
MUZ-LN60VG3/MSZ-LN60VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
FDC100VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.53 | 4.29 | -15° | 10.00 | 6.40 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
ROG36KBTA5/RSG18KMTB/RSG18KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOEG36KBTA5/ASEG18KMTE/ASEG18KMTE
AOE**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
SRC71ZR-W/SRK71ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -15° | 7.10 | 6.60 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 |