Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(9)
ATLANTIC
(0)
AUX
(18)
BOSCH
(9)
BRYANT
(0)
Buderus
(0)
CARRIER
(11)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(73)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(2)
GSS
(0)
HAIER
(48)
HEC
(0)
HEIWA
(0)
HISENSE
(13)
HITACHI
(19)
IVT
(0)
Inventor
(7)
KAYSUN
(10)
LG
(2)
MIDEA
(51)
MITSUBISHI ELECTRIC
(97)
Mitsubishi Heavy Industries
(36)
NORD
(0)
Nobu
(0)
PANASONIC
(16)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(39)
Viessmann
(6)
Vulcano
(0)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-100PZH4E5 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 | |
|
PUZ-ZM100VDA/PLA-ZM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PLA-ZM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PLA-ZM50EA2/PLA-ZM50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PLA-ZM50EA3/PLA-ZM50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PLA-ZM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PLA-ZM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MY1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.67 | 5.62 | 5.62 | 13.40 | 7.80 | ||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.67 | 5.62 | 5.62 | 13.40 | 7.80 | ||
|
PUZ-ZM100YDA/PLA-ZM50EA2/PLA-ZM50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PLA-ZM50EA3/PLA-ZM50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
AOEG36KBTA5/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
MUZ-RZ50VUHZ/MSZ-RZ50VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -30° | 5.00 | 6.00 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
RZAG100NV1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NV1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
AOEG30KBTA4/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOHG30KBTA4/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
AOEG24KBCA3/ASEH07KMCG/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTA3/ASHH07KMCG/ASHH09KMCG/ASHH09KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
PUZ-ZM100YDA/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
AUW105U4RW8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
AUW105U4RW8/AUD105UX4RQM8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.10 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUD105UX4RQM8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.10 | -10° | 10.00 | 8.00 |