Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(13)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(23)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
PITSOS
(0)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
XTRON
(0)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
KUE-90 DVR13/KCIS-90 DR14
ZEN Cassette
|
KAYSUN | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YUKF30BYEEBMO-1/YKKF30BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
AD105S2SM9FA(H)/1U105S2SQ1FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
YDAM-100R-09M22/DDHM-100N-09M22
OASIS
|
AIRWELL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
RAV-GM1101ATP-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101KRTP-E
DI 3ph
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 | |
|
RAV-GM1102AT8W-E/RAV-HM1101KRTP-E
DI 3ph
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.31 | -15° | 9.50 | 8.00 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOEG24KLCA/ASEG24KLCA
ASE**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
MXZ-5F102VF2/MSZ-AY42VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-5F102VF3/MSZ-AY42VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
U-100PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
M4OA-27HFN8-Q(HRU)/MSAGAU-09HRFN8-QRD1GW+MSAGCU-18HRFNX-QRD0GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 7.90 | 6.20 | |
|
AL-H36/4DR3C3(U) / AUMD-H36/4DR3HC2
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDMD105M-B
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
PUZ-M100VKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
RAV-GM1601ATP-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.47 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.47 | -15° | 14.00 | 8.00 | |
|
RAS-24P2AVSG-E/RAS-B24P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -20° | 7.00 | 6.30 | |
|
RAS-24P2AVSG-E/RAS-B24P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -20° | 7.00 | 6.30 | |
|
RAV-GV1601ATP-E1/RAV-HM1601BTP-E
DIC 1ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
SCM100ZS-W/SRK50ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 4.00 | -10° | 10.00 | 6.80 |