Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GWHD(24)NK6QO GWH12AGCXD-K6DNA1D/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 7.10 | 6.10 | |
|
M4OA-27HFN8-Q(HRU)/MSAFAU-09HRFN8-QRD1GW+MSAFCU-18HRFNX-QRD0GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.48 | -10° | 7.90 | 6.20 | |
|
AL-H36/4DR3C3(U) / AUCA-H36/4DR3HB2
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCA105Q-B
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RDG30KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXG30KMLA
ARXG**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
FDC100VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RCG30KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/AUXG30KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/AUXG30KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
ADH125H1ERG/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.94 | 3.40 | 12.30 | 8.00 | ||
|
AL-H24/4DR3HB3(U) / AUCA-H24/4DR3HB2
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RXYL71M-T1B/FDCA71Q-B
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RAS-4HVRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
RAV-GM1402ATW-E/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.90 | 3.29 | -15° | 12.10 | 8.30 | |
|
RZASG100MV1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
AUW105U4RK7/AUC105UR4RKC8
Super Inverter R32
|
HISENSE | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 8.00 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.17 | 3.46 | -15° | 13.00 | 8.00 | |
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
3U80S2LR1FA/AS35PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 8.00 | 6.00 | |
|
4U85S2LR1FA/AS35PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 8.50 | 6.00 | |
|
RZASG100MV1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
AD125S2SM8FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
AD125S2SM8FA(H)/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
AD125S2SM9FA(H)/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
RAV-GV1101ATP-E/RAV-HM1101KRTP-E
DIC
|
TOSHIBA | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.03 | -15° | 9.50 | 7.60 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(M*)+AMWM-H18/4R3HA(M*)
M SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(C*)+AMWM-H18/4R3HA(C*)
C SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 |