Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MXZ-4F72VF4/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
MXZ-4F72VF5/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG2/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
AOYG30KBTB/AUXG30KRLB
AUY**K
|
FUJITSU | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/AUXG30KRLB
AUH**K
|
GENERAL | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RCG30KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/AUXG30KRLB
AUXG**K
|
FUJITSU | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/AUXG30KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTA4/ASYG07KMCC/ASYG22KMTB
AOY**K Multi
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOHG30KBTA4/ASHG07KMCC/ASHG22KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
ROG30KBTA4/RSG07KMCC/RSG22KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOEG30KBTA4/ASEH07KMCG/ASEG22KMTE
AOE**K Multi
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOYG30KBTA4/ASYG07KMCC/ASYG22KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
RAV-GM1602AT8W-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.44 | -15° | 14.00 | 8.00 | |
|
PUZ-ZM100YDA/PEAD-M50JA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PEAD-M50JAL2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M50JA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M50JAL3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
GUD85T1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.30 | -10° | 8.50 | 6.00 | ||
|
FDC71VNX-W/FDF71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDF71VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
AOYG24KBTB/ARXG24KHTAP
ARY**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXG24KHTAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RDG24KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ARXG24KHTAP
ARXG**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXG24KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
MXZ-4F83VF2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
MXZ-4F83VF3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
RZASG140MV
RZASG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.31 | 13.40 | 7.00 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.31 | 13.40 | 7.00 | |||
|
RAV-GM1402AT8W-E/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.91 | 4.30 | 3.83 | -15° | 12.10 | 8.00 | |
|
MXZ-5F102VF2/MSZ-LN50VG2/MSZ-LN50VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.57 | -15° | 8.30 | 8.00 | |
|
MXZ-5F102VF3/MSZ-LN50VG3/MSZ-LN50VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.57 | -15° | 8.30 | 8.00 | |
|
PXZ-5F85VG/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.76 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
PXZ-5F85VG2/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.76 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
3U63S2LD1FA/AS35PBPHRA-PRE+AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.20 | 4.40 | -10° | 6.30 | 6.60 | |
|
42QSS030D8S*/38QUS030D8S*
Ducted
|
CARRIER | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
DC280HIDS8/AIC280HIDS8
Ducted
|
RIELLO | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
PUZ-M100YKA2/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA2/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 |