Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(13)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(23)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
PITSOS
(0)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
XTRON
(0)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q(GA)/MTI-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q/MTI-30HNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
YUKF30BYEEBMO-1/YEKF30BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
AOEH36KMTB/ASEH36KMTB
ASE**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOHH36KMTB/ASHH36KMTB
ASY**K
|
GENERAL | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
ROH36KMTB/RSH36KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RAV-GM902ATW-E/RAV-HM901FT-E
DI
|
TOSHIBA | Floor standing | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.00 | 3.70 | -15° | 8.00 | 6.30 | |
|
PUZ-ZM100VKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 1.90 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/AUXG24KRLB
AUXG**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RAV-GM1602ATW-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.05 | 3.38 | -15° | 14.00 | 8.40 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
RAV-GM1101ATP-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RPFC-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -15° | 8.60 | 6.50 | |
|
AD125S2SM9FA(H)/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
AD125S2SM9FA(H)/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
42QTD030D8S*/38QUS030D8S*
Cassette
|
CARRIER | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
KC280HIDS8/AIC280HIDS8
Cassette
|
RIELLO | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42QSS036D8S*/38QUS036D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 |