Filters · 4 active
Manufacturer:
AIRCLASS
Buderus
COLIBRI
GSS
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
CARRIER
(149)
CIAT
(44)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC186i.3-2,6 / AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-2,6 / AC186i.3-2,6 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-2,0 / AC186i.3-2,0 W
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC186i.3-2,0 / AC186i.3-2,0 WB
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC-7,9 MS E+ / AC186i.3-5,3 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AC186i.3-5.3 / AC186i.3-5.3 W
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC186i.3-5,3 / AC186i.3-5,3 WB
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC-5,3 MS E+ / AC186i.3-2,6 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
COLI09D8SHF/COLI09D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC186i.3-4,1 / AC186i.3-4,1 W
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC186i.3-4,1 / AC186i.3-4,1 WB
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC176i.3-2,6 / AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
AITO-18322.MH/AIT-18322.MH
AIT
|
AIRCLASS | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC176i.3-5,3 / AC176i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AITO-24322.MH/AIT-24322.MH
AIT
|
AIRCLASS | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AC176i.3-7,0 / AC176i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AC176i.3-3,5 / AC176i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
COLI12D8SHF/COLI12D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
COLI18R8SHF/COLI18R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
AC166i.2-3,5 / AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC166i.2-3,5 / AC166i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC-5,3 MS / AC166i-2,6 MS CN + AC166i-2,6 MS CN
Logacool
|
Buderus | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AC166i.2-7,0 / AC166i.2-7,0 W
Logacool
|
Buderus | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC166i.2-7,0 / AC166i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC166i.2-2,6 / AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AC166i.2-2,6 / AC166i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AC-4,1 MS / AC166i.2-2,6 W + AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
AC-10,6 MS / AC166i.2-5,3 W+ AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
AC-4,1 MS / AC166i-2,1 MS D + AC166i-2,1 MS D
Logacool
|
Buderus | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
GSX-IDU-024/GSX-ODU-024
GSX
|
GSS | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
GSX-IDU-012/GSX-ODU-012
GSX
|
GSS | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.73 | -10° | 3.50 | 2.60 | |
|
AC-5,3 MS / AC166i-2,6 MS D + AC166i-2,6 MS D
Logacool
|
Buderus | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AC-5,3 MS / AC176i.3-2,6 W + AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AC-6,2 MS / AC166i.2-2,6 W + AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
AC-7,9 MS / AC166i.2-2,6 W + AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
AC-5,3 MS / AC166i.2-2,6 W + AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
GSX-IDU-018/GSX-ODU-018
GSX
|
GSS | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
COLI09R8SHF/COLI09R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
AC-8,2 MS / AC166i.2-2,6 W + AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 |