Filters · 4 active
Manufacturer:
AIRCLASS
GSS
RIELLO
Vulcano
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
AIX250HIM8-2/DC225HIM8*
Ducted
|
RIELLO | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
WR225HJM8-1/AIR225HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
WR650HJM8*/AIR650HJM8*
Wall mounted
|
RIELLO | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.77 | -10° | 5.20 | 4.30 | |
|
SC210HIDS8/AIC210HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
WR670HJM8*/AIR670HJM8*
Wall mounted
|
RIELLO | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
AITO-18322.MH/AIT-18322.MH
AIT
|
AIRCLASS | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
DC280HIDS8/AIC280HIDS8
Ducted
|
RIELLO | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
AITO-24322.MH/AIT-24322.MH
AIT
|
AIRCLASS | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC250HIDS8*/AIC250HIDS8*
Console
|
RIELLO | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
WR235HJM8-1/AIR235HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
DC250HIDS8/AIC250HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
KC280HIDS8/AIC280HIDS8
Cassette
|
RIELLO | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
DC210HIDS8/AIC210HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
DC217HIDS8/AIC217HIDT8
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
DC212HIDS8*/AIC212HIDS8*
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
KC235HIDS8/AIC235HIDS8
Cassette
|
RIELLO | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
DC213HIDS8/AIC213HIDT8
Ducted
|
RIELLO | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
DC235HIDS8/AIC235HIDS8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
DC210HIDS8/AIC210HIDT8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
KC210HIDS8/AIC210HIDS8
Cassette
|
RIELLO | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
SC210HIDS8/AIC210HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
DC270HIDS8/AIC270HIDS8
Ducted
|
RIELLO | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
SC213HIDS8/AIC213HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
KC210HIDS8/AIC210HIDT8
Cassette
|
RIELLO | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
SC250HIDS8/AIC250HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
KC217HIDS8/AIC217HIDT8
Cassette
|
RIELLO | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.21 | 15.00 | 11.80 | ||
|
AIX250HIM8-2/WR525HJM8*
Wall mounted
|
RIELLO | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 3.67 | -10° | 5.35 | 4.40 | |
|
SC217HIDS8/AIC217HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
WR050HJM8-1/AIR050HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
WR535HJM8*/AIR535HJM8*
Wall mounted
|
RIELLO | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
WR525HJM8*/AIR525HJM8*
Wall mounted
|
RIELLO | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.85 | -10° | 2.75 | 2.50 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
KC212HIDS8*/AIC212HIDS8*
Cassette
|
RIELLO | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
WR025HJM8-W/AIR025HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
KC213HIDS8/AIC213HIDT8
Cassette
|
RIELLO | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.49 | 14.00 | 10.80 | ||
|
KC250HIDS8/AIC250HIDS8
Cassette
|
RIELLO | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.47 | -10° | 5.30 | 4.20 | |
|
WR550HJM8*/AIR550HJM8*
Wall mounted
|
RIELLO | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.35 | -10° | 5.28 | 4.10 | |
|
KC270HIDS8/AIC270HIDS8
Cassette
|
RIELLO | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
WR570HJM8*/AIR570HJM8
Wall mounted
|
RIELLO | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AIX250HIM8-2/KC225HIM8*
Cassette
|
RIELLO | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 |