Filters · 3 active
Manufacturer:
AIRWELL
EQUATION
AIRCLASS
(0)
ATLANTIC
(8)
AUX
(0)
BOSCH
(17)
BRYANT
(3)
Buderus
(3)
CARRIER
(42)
CIAT
(18)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(201)
FUJI ELECTRIC
(23)
FUJITSU
(57)
Fujitsu Atlantic
(28)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(185)
HEC
(3)
HEIWA
(0)
HISENSE
(33)
HITACHI
(35)
IVT
(0)
Inventor
(51)
KAYSUN
(33)
LG
(49)
MIDEA
(258)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(99)
NORD
(25)
Nobu
(6)
PANASONIC
(13)
RIELLO
(20)
Rotenso
(7)
SAMSUNG
(45)
THERMOR
(11)
TOSHIBA
(79)
Viessmann
(8)
Vulcano
(4)
WESTPOINT
(0)
YORK
(20)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDMX-100N-09M25/YDAX-100H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
DDMD-100N-09M25/YDAX-100H-09M25**
DDMD
|
AIRWELL | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
DDMD-100N-09M25/YDAX-100H-09T35**
DDMD
|
AIRWELL | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CDMX-100N-09M25/YDAX-100H-09M25
CDMX
|
AIRWELL | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
FDMX-100N-09M25/YDAX-100H-09T35
FDMX
|
AIRWELL | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
CDMX-100N-09M25/YDAX-100H-09T35
CDMX
|
AIRWELL | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
FDMX-070N-09M25/YDAX-070H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
HDMB-070N-09M22-GY/YDAB-070H-09M22
Harmonia
|
AIRWELL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.43 | -10° | 7.00 | 4.90 | |
|
HDMB-070N-09M22/YDAB-070H-09M22
Harmonia
|
AIRWELL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.43 | -10° | 7.00 | 4.90 | |
|
HDMB-070N-09M22-MR/YDAB-070H-09M22
Harmonia
|
AIRWELL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.43 | -10° | 7.00 | 4.90 | |
|
CDMX-070N-09M25/YDAX-070H-09M25
CDMX
|
AIRWELL | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
ZDAA-4090-09M25/HDLA-050N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
HDLA-070N-09M25/YDAA-070H-09M25
Aura
|
AIRWELL | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
HDLA-035N-09M25/YDAA-035H-09M25
Aura
|
AIRWELL | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 |