Filters · 3 active
Manufacturer:
AIRWELL
GREE
AIRCLASS
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(0)
Inventor
(0)
KAYSUN
(10)
LG
(0)
MIDEA
(67)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(2)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
COP up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD71ZD1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | -10° | 7.10 | 4.70 | ||
|
GUD85ZD1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | -10° | 8.50 | 6.00 | ||
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
FDMX-100N-09M25/YDAX-100H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
FDMX-070N-09M25/YDAX-070H-09M25 2026
FDMX
|
AIRWELL | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
FDMX-100N-09M25/YDAX-100H-09T35
FDMX
|
AIRWELL | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
FDMX-070N-09M25/YDAX-070H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 |