Filters · 3 active
Manufacturer:
ATLANTIC
AUX
AIRCLASS
(1)
AIRWELL
(64)
BOSCH
(63)
BRYANT
(6)
Buderus
(19)
CARRIER
(94)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(381)
EQUATION
(4)
FUJI ELECTRIC
(115)
FUJITSU
(285)
Fujitsu Atlantic
(145)
GENERAL
(147)
GREE
(80)
GSS
(4)
HAIER
(430)
HEC
(5)
HEIWA
(4)
HISENSE
(171)
HITACHI
(76)
IVT
(1)
Inventor
(111)
KAYSUN
(65)
LG
(201)
MIDEA
(636)
MITSUBISHI ELECTRIC
(361)
Mitsubishi Heavy Industries
(180)
NORD
(38)
Nobu
(8)
PANASONIC
(133)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(103)
THERMOR
(43)
TOSHIBA
(124)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(7)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AL-H30/4DR3HB3(U) / AUMD-H30/4DR3HC2
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
RXYL90M-T1B/FDMD90M-B
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
AS 018 NBB.UI/1U 018 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.00 | -10° | 5.20 | 4.60 | |
|
AL-H36/4DR3C3(U) / AUMD-H36/4DR3HC2
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDMD105M-B
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
AL-H36/4DR3C3(U) / AUCF-H36/4DR3HC2
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCF105F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
AS 012 NBB.UI/1U 012 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
UI 3,6 kW MURAO SMART BLANC & UE MONO 3,6 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AL-H12/4DR3HD1(U) / AUMD-H12/4DR3HB2
M-Ducted
|
AUX | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
RXYL35M-T1B/FDMD35M-B
M-Ducted
|
AUX | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
AL-H18/4DR3HB3(U) / AUMD-H18/4DR3HB2
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
RXYL52M-T1B/FDMD52M-B
M-Ducted
|
AUX | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
AL-H18/4DR3HB3(U) / AUCF-H18/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
RXYL52M-T1B/FDCF52F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
AL-H24/4DR3HB3(U) / AUMD-H24/4DR3HB2
M-Ducted
|
AUX | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RXYL71M-T1B/FDMD71M-B
M-Ducted
|
AUX | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
AC 036 DB.UI/1U 036 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.23 | -10° | 9.50 | 7.00 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AL-H36/4DR3C3(U) / AUCA-H36/4DR3HB2
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCA105Q-B
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
AL-H24/4DR3HB3(U) / AUCA-H24/4DR3HB2
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RXYL71M-T1B/FDCA71Q-B
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(M*)+AMWM-H18/4R3HA(M*)
M SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(C*)+AMWM-H18/4R3HA(C*)
C SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM80M(4)-T1A+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM80M(4)-T1A+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
AM3-H27/4DR3D+AMWM-H09/4R3HA(M*)+AMWM-H18/4R3HA(M*)
M SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -10° | 7.91 | 5.50 | |
|
AM3-H27/4DR3D+AMWM-H09/4R3HA(C*)+AMWM-H18/4R3HA(C*)
C SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -10° | 7.91 | 5.50 | |
|
RXYM80M(3)-T1B+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -10° | 7.91 | 5.50 | |
|
RXYM80M(3)-T1B+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -10° | 7.91 | 5.50 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
AC 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Convertible
|
ATLANTIC | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.21 | 12.40 | 8.00 | ||
|
AM2-H18/4DR3C+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -10° | 5.30 | 4.50 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.04 | 2.81 | -10° | 5.40 | 4.40 |