Filters · 3 active
Manufacturer:
AIRWELL
BOSCH
AIRCLASS
(0)
ATLANTIC
(20)
AUX
(66)
BRYANT
(6)
Buderus
(18)
CARRIER
(118)
CIAT
(40)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(627)
EQUATION
(3)
FUJI ELECTRIC
(150)
FUJITSU
(360)
Fujitsu Atlantic
(182)
GENERAL
(202)
GREE
(91)
GSS
(4)
HAIER
(441)
HEC
(5)
HEIWA
(4)
HISENSE
(261)
HITACHI
(141)
IVT
(1)
Inventor
(109)
KAYSUN
(64)
LG
(321)
MIDEA
(648)
MITSUBISHI ELECTRIC
(552)
Mitsubishi Heavy Industries
(352)
NORD
(40)
Nobu
(8)
PANASONIC
(254)
RIELLO
(43)
Rotenso
(8)
SAMSUNG
(167)
THERMOR
(43)
TOSHIBA
(265)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(3)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
DDMD-090N-09M25/YDAX-090H-09M25**
DDMD
|
AIRWELL | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
DDMD-070N-09M25/YDAX-070H-09M25**
DDMD
|
AIRWELL | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
FDMX-100N-09M25/YDAX-100H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
DDMD-035N-09M25/YDAX-035H-09M25**
DDMD
|
AIRWELL | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
HDMC-070N-09M25/YDA*-070*-09M25
Harmonia
|
AIRWELL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
ZDAB-2050-09M25/HDHC-025N-09M25x2
ZDAB
|
AIRWELL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
DDMD-050N-09M25 /YDAX-050H-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
DDMD-100N-09M25/YDAX-100H-09M25**
DDMD
|
AIRWELL | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
YDAM-050R-09M25/FDHM-050N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
FDMX-070N-09M25/YDAX-070H-09M25 2026
FDMX
|
AIRWELL | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
XDMX-025N-09M25/YDAX-025R-09M25**
XDMX
|
AIRWELL | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CDMD-035N-09M25/YDAX-035H-09M25**
CDMD
|
AIRWELL | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
YDAM-100R-09M22/FDHM-100N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YDAM-100R-09M22/DDHM-100N-09M22
OASIS
|
AIRWELL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
DDMD-100N-09M25/YDAX-100H-09T35**
DDMD
|
AIRWELL | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
YDAM-070R-09M22/DDHM-070N-09M22
OASIS
|
AIRWELL | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.00 | 3.80 | -10° | 7.10 | 5.00 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CDMX-100N-09M25/YDAX-100H-09M25
CDMX
|
AIRWELL | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 |