Filters · 3 active
Manufacturer:
BOSCH
FUJITSU
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(5)
AUX
(1)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(183)
EQUATION
(0)
FUJI ELECTRIC
(43)
Fujitsu Atlantic
(61)
GENERAL
(55)
GREE
(0)
GSS
(0)
HAIER
(135)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(27)
IVT
(0)
Inventor
(11)
KAYSUN
(6)
LG
(58)
MIDEA
(49)
MITSUBISHI ELECTRIC
(167)
Mitsubishi Heavy Industries
(123)
NORD
(0)
Nobu
(0)
PANASONIC
(23)
RIELLO
(1)
Rotenso
(5)
SAMSUNG
(27)
THERMOR
(4)
TOSHIBA
(76)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEG45KBTB/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG36LATT/ARYG36LMLA
ARY**L
|
FUJITSU | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.90 | -15° | 10.00 | 10.00 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOEG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG45KBTB/ARXG45KHTA
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTB
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTA
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTB
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTA
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTB
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KHTB
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOEG12KATA/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG54LATT/AUYG54LRLA
AOYG**L
|
FUJITSU | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.09 | 3.61 | 14.00 | 10.40 | ||
|
AOEG24KATA/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOEG22KATA/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ARXH36KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ARXH36KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/ARXH36KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXH36KMTAP
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 |