Filters · 3 active
Manufacturer:
BOSCH
GENERAL
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(41)
AUX
(70)
BRYANT
(6)
Buderus
(32)
CARRIER
(140)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(769)
EQUATION
(5)
FUJI ELECTRIC
(160)
FUJITSU
(389)
Fujitsu Atlantic
(193)
GREE
(120)
GSS
(4)
HAIER
(572)
HEC
(5)
HEIWA
(8)
HISENSE
(319)
HITACHI
(163)
IVT
(8)
Inventor
(147)
KAYSUN
(70)
LG
(339)
MIDEA
(825)
MITSUBISHI ELECTRIC
(595)
Mitsubishi Heavy Industries
(383)
NORD
(56)
Nobu
(8)
PANASONIC
(289)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(194)
THERMOR
(58)
TOSHIBA
(278)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG18KBTA3/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG18KBTA2/ASHG09KGTB/ASHG09KGTB
AOH**K Multi
|
GENERAL | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOHG18KBTA2/ASHH09KGTG/ASHH09KGTG
AOH**K Multi
|
GENERAL | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOHG30KBTA4/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOHG24KBTA3/ASHH07KMCG/ASHH09KMCG/ASHH09KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG14KBTA2/ASHG07KGTB/ASHG07KGTB
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOHG14KBTA2/ASHH07KGTG/ASHH07KGTG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
AOHG09KBTB/ARXG09KLLAP
ARH**K
|
GENERAL | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOHH18KMTG/ASHH18KMTGL
ASH**K
|
GENERAL | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOHG18KMTA/ASHG18KMTE
ASH**K
|
GENERAL | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AOHH14KGCG/ASHH14KGTG
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTH
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOHG14KMCEN/ASHG14KMCEN
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOHG14KMCEN/ASHG14KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOHG12KBTB/ARXG12KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG18KBTB/AUXG18KRLB
AUH**K
|
GENERAL | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
AOHG12KMCEN/ASHG12KMCEN
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 |