Filters · 3 active
Manufacturer:
BOSCH
HAIER
AIRCLASS
(1)
AIRWELL
(64)
ATLANTIC
(26)
AUX
(56)
BRYANT
(6)
Buderus
(19)
CARRIER
(94)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(381)
EQUATION
(4)
FUJI ELECTRIC
(115)
FUJITSU
(285)
Fujitsu Atlantic
(145)
GENERAL
(147)
GREE
(80)
GSS
(4)
HEC
(5)
HEIWA
(4)
HISENSE
(171)
HITACHI
(76)
IVT
(1)
Inventor
(111)
KAYSUN
(65)
LG
(201)
MIDEA
(636)
MITSUBISHI ELECTRIC
(361)
Mitsubishi Heavy Industries
(180)
NORD
(38)
Nobu
(8)
PANASONIC
(133)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(103)
THERMOR
(43)
TOSHIBA
(124)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(7)
YORK
(37)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AC50S2SG2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
AD35S2SM3FA/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 3.50 | 2.70 | |
|
AD140S2SM8FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
3U63S2LD1FA/AS35PBPHRA-PRE+AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.20 | 4.40 | -10° | 6.30 | 6.60 | |
|
ADH140H1ERG/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.18 | 4.10 | 3.72 | 13.60 | 10.00 | ||
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AP105S2SK1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.60 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AC71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.20 | 3.52 | -10° | 7.10 | 5.00 | |
|
AD140S2SM3FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
ADH140H1ERG/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.07 | 3.72 | 13.60 | 10.00 | ||
|
AD140S2SM3FA/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
AD125S2SM9FA(H)/1U125S2SN3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
AD125S2SM9FA(H)/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.05 | 3.72 | 12.40 | 8.30 | ||
|
AP71DFMHRA/1U71WEMFRA
New Cabinet RAC
|
HAIER | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
AD160S2SM3FA/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM3FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM9FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
2U70S2SR1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
2U70S2LD1FA/AS25PBPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.05 | 3.70 | -10° | 6.80 | 6.80 | |
|
AP140S2SK1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 4.00 | 2.76 | 13.40 | 8.50 | ||
|
AS35XCHHRA-NR/1U35KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.20 | -10° | 3.50 | 3.60 | |
|
AS105PFAHRA/1U105XEAFRA
HAIER - QUARTZ
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AS105PFAHRA/1U105XEAFRA-H
Wall mounted - Quartz
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 |