Filters · 3 active
Manufacturer:
BOSCH
HAIER
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(112)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(14)
IVT
(0)
Inventor
(8)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(43)
Mitsubishi Heavy Industries
(64)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(29)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC71S2SG2FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.25 | 3.26 | -10° | 7.10 | 5.00 | |
|
AC50S2SG2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.20 | 3.52 | -10° | 7.10 | 5.00 | |
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC105S2SH2FA(H)/1U105S2SQ1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
AC140S2SK1FA/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
AC140S2SK1FA(H)/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
AC140S2SK2FA(H)/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
AC140S2SK1FA/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
AC140S2SK1FA(H)/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
AC140S2SK2FA(H)/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
AC71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.00 | 3.52 | -10° | 7.10 | 5.00 | |
|
AC160S2SK2FA(H)/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AC105S2SH1FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC160S2SK1FA/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AC160S2SK1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AC71S2SG2FA(H)/1U71S2SR3FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC105S2SH1FA/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 4.00 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC125S2SK2FA(H)/1U125S2SN3FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
AC125S2SK2FA(H)/1U125S2SN3FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
AC71S2SG1FA/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
AC140S2SK1FA/1U140S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | 13.40 | 11.00 | ||
|
AC140S2SK1FA/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
AC105S2SH2FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.91 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC125S2SK1FA/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK1FA/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC140S2SK1FA/1U140S2SP1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.70 | 13.40 | 11.00 | ||
|
AC105S2SH1FA/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH2FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH1FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC71S2SG2FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC125S2SK1FA/1U125S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 3.81 | 3.42 | 12.10 | 8.00 | ||
|
AC125S2SK1FA/1U125S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 3.81 | 3.60 | 12.10 | 8.00 |