Filters · 3 active
Manufacturer:
BOSCH
HISENSE
AIRCLASS
(0)
AIRWELL
(43)
ATLANTIC
(19)
AUX
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(59)
CIAT
(32)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(239)
EQUATION
(4)
FUJI ELECTRIC
(68)
FUJITSU
(173)
Fujitsu Atlantic
(85)
GENERAL
(81)
GREE
(35)
GSS
(4)
HAIER
(349)
HEC
(5)
HEIWA
(3)
HITACHI
(43)
IVT
(0)
Inventor
(78)
KAYSUN
(46)
LG
(156)
MIDEA
(361)
MITSUBISHI ELECTRIC
(148)
Mitsubishi Heavy Industries
(87)
NORD
(19)
Nobu
(6)
PANASONIC
(60)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(66)
THERMOR
(41)
TOSHIBA
(74)
Viessmann
(8)
Vulcano
(14)
WESTPOINT
(0)
YORK
(32)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
AUF140UR4RMPA8/AUW140U6RQ7
Turbo Inverter R32
|
HISENSE | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.54 | -10° | 13.50 | 8.50 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
AUW105U4RK7/AUD105UX4RQM8
Super Inverter R32
|
HISENSE | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
AUD175UX4REH8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 16.00 | 10.00 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
AUD200UX4RPH8/AUW200U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -10° | 19.00 | 17.00 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
AUD250UX4RPH8/AUW250U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 3.90 | 3.45 | -10° | 23.00 | 17.00 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AUW105U4RK7/AUC105UR4RKC8
Super Inverter R32
|
HISENSE | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 8.00 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
AUC175UR4RKC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 2.97 | -10° | 16.00 | 10.00 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AUV175UR4RC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.30 | -10° | 16.00 | 10.00 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AS70BT2BW/CA70BT2BG
Easy Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KE70BT2BG
Ultra Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KF70BT2BG
Expert Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KB70BT2BG
Wings Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KE70BT2BG
Ultra Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KF70BT2BG
Expert Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KB70BT2BG
Wings Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/CF70BT2BG
Hi Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
CA70BT2BW/CA70BT2BG
Easy Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
ATBT242RW/CBBT242RG
Halo
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
ATBT242RW/CDBT242RG
Pearl
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 |