Filters · 3 active
Manufacturer:
BOSCH
HISENSE
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(4)
AUX
(8)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(156)
EQUATION
(0)
FUJI ELECTRIC
(33)
FUJITSU
(68)
Fujitsu Atlantic
(35)
GENERAL
(35)
GREE
(6)
GSS
(0)
HAIER
(63)
HEC
(0)
HEIWA
(0)
HITACHI
(31)
IVT
(0)
Inventor
(16)
KAYSUN
(17)
LG
(52)
MIDEA
(96)
MITSUBISHI ELECTRIC
(133)
Mitsubishi Heavy Industries
(84)
NORD
(6)
Nobu
(0)
PANASONIC
(32)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(38)
THERMOR
(4)
TOSHIBA
(47)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AUW60U4RK8/ACT60UR4RJC8
Turbo Inverter R32
|
HISENSE | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 4.00 | -10° | 6.20 | 5.50 | |
|
AUW105U4RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW71U4RK8/ACT71UR4RJC8
Turbo Inverter R32
|
HISENSE | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.80 | -10° | 7.00 | 5.50 | |
|
AUW40U4RJ8/ACT40UR4RJC8
Turbo Inverter R32
|
HISENSE | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 4.50 | -10° | 4.10 | 4.00 | |
|
AUW26U4RS8/ACT26UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 4.27 | -10° | 2.60 | 3.00 | |
|
AUW52U4RJ8/ACT52UR4RJC8
Turbo Inverter R32
|
HISENSE | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.30 | -10° | 5.00 | 4.00 | |
|
AUW35U4RS8/ACT35UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
AUC125UR4RKC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.50 | 3.80 | -10° | 12.10 | 9.00 | |
|
AUC125UR4RKC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.50 | 3.80 | -10° | 12.10 | 9.00 | |
|
AUW105U6RN8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -10° | 10.00 | 8.00 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUW40U4RJ8/ACT40UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.00 | -10° | 4.10 | 4.00 | |
|
AUW52U4RJ8/ACT52UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 3.71 | -10° | 5.00 | 4.00 | |
|
AUC125UR4RKC8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 3.65 | -10° | 12.10 | 9.00 | |
|
AUW60U4RJ7/ACT60UR4RJC8
Super Inverter R32
|
HISENSE | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.80 | -10° | 6.20 | 5.50 | |
|
AUC140UR4RKC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.07 | 4.40 | 2.94 | -10° | 13.50 | 9.00 | |
|
AUW71U4RJ7/ACT71UR4RJC8
Super Inverter R32
|
HISENSE | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.72 | -10° | 7.00 | 5.50 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
AUW40U4RS7/ACT40UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.90 | -10° | 4.10 | 4.00 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
AUW52U4RS7/ACT52UR4RCC8
Super Inverter R32
|
HISENSE | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -10° | 5.00 | 4.00 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
AUW105U4RK7/AUC105UR4RKC8
Super Inverter R32
|
HISENSE | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 8.00 | |
|
AUC175UR4RKC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 2.97 | -10° | 16.00 | 10.00 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 |