Filters · 3 active
Manufacturer:
BOSCH
HITACHI
AIRCLASS
(2)
AIRWELL
(55)
ATLANTIC
(22)
AUX
(63)
BRYANT
(2)
Buderus
(20)
CARRIER
(96)
CIAT
(35)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(4)
DAIKIN
(717)
EQUATION
(3)
FUJI ELECTRIC
(111)
FUJITSU
(297)
Fujitsu Atlantic
(140)
GENERAL
(155)
GREE
(65)
GSS
(2)
HAIER
(438)
HEC
(1)
HEIWA
(4)
HISENSE
(177)
IVT
(5)
Inventor
(94)
KAYSUN
(54)
LG
(235)
MIDEA
(526)
MITSUBISHI ELECTRIC
(493)
Mitsubishi Heavy Industries
(370)
NORD
(38)
Nobu
(4)
PANASONIC
(225)
RIELLO
(36)
Rotenso
(8)
SAMSUNG
(113)
THERMOR
(29)
TOSHIBA
(216)
Viessmann
(17)
Vulcano
(12)
WESTPOINT
(8)
YORK
(28)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.25 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
RAM-G55N2HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
RAM-G55N2HBE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
RAC-XJ50WHAE / RAK-XJ50RHAE
RAC-XJ-WHAE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAM-G70N4HAE / RAK-XJ35RHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.62 | 4.20 | -15° | 7.00 | 5.90 | |
|
RAC-50WXEN / RAK-50RXE
RAC-WXEN
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAM-G55N3HCE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 4.20 | -10° | 5.50 | 5.60 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
RAM-G55N3HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.76 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
RAM-G55N2HCE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 5.50 | 5.60 | |
|
RAC-50NPE / RAK-50RPE1
RAC-NPE(D)
|
HITACHI | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.16 | 4.61 | 4.00 | -15° | 5.00 | 4.70 | |
|
RAC-50FXE / RAF-50RXE
RAC-FXE
|
HITACHI | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.80 | -20° | 5.00 | 4.61 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
RAM-G70N4HCE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
RAM-G68N3HCE / RAK-XJ18QHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.00 | -10° | 6.80 | 5.90 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
RAM-90NYP5E / RAK-35RXE / RAK-50RXE
RAM-NYPE
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.90 | -15° | 8.50 | 7.10 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RAS-4HVRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.93 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 |