Filters · 3 active
Manufacturer:
BOSCH
FUJITSU
Vulcano
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEH09KHCBN/ASEH09KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
AOEH09KHCBN/ASEH09KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
AOEH12KHCBN/ASEH12KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOEH12KHCBN/ASEH12KHCBN-B
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOEH14KHCBN/ASEH14KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
AOEH14KHCBN/ASEH14KHCBN-B
ASE**K
|
FUJITSU | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
AOEH07KGCG/ASEH07KGTG
ASE**K
|
FUJITSU | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.80 | 5.20 | 5.00 | -15° | 2.00 | 2.30 | |
|
AOYH07KGCG/ASYH07KGTG
ASY**K
|
FUJITSU | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.80 | 5.20 | 5.00 | -15° | 2.00 | 2.30 | |
|
AOYG07KGCA/ASYG07KGTE
ASY**K
|
FUJITSU | Wall mounted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.30 | 5.00 | -15° | 2.00 | 2.30 | |
|
AOEH09KGCG/ASEH09KGTG
ASE**K
|
FUJITSU | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.20 | 4.67 | -15° | 2.50 | 2.40 | |
|
AOYH09KGCG/ASYH09KGTG
ASY**K
|
FUJITSU | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.20 | 4.67 | -15° | 2.50 | 2.40 | |
|
AOYG09KGCA/ASYG09KGTE
ASY**K
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.20 | 5.00 | -15° | 2.50 | 2.40 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
AOYG12KGCA/ASYG12KGTE
ASY**K
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOEH07KJCA/ASEH07KJCAL
ASE**K
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.60 | 5.10 | 5.00 | -20° | 2.00 | 2.30 | |
|
AOEH07KJCA/ASEH07KJCALB
ASE**K
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.60 | 5.10 | 5.00 | -20° | 2.00 | 2.30 | |
|
AOYG09KGCB/ASYG09KGTF
ASY**K
|
FUJITSU | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 5.20 | 5.00 | -15° | 2.50 | 2.40 | |
|
AOEH12KGCG/ASEH12KGTG
ASE**K
|
FUJITSU | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOYH12KGCG/ASYH12KGTG
ASY**K
|
FUJITSU | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOEG36KBTA5/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOEH09KJCA/ASEH09KJCAL
ASE**K
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOEH09KJCA/ASEH09KJCALB
ASE**K
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
AOYG18KBTA2/ASYG09KGTB/ASYG09KGTB
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYG09KGTE/ASYG09KGTE
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOEG18KBCA2/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYH09KGTG/ASYH09KGTG
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOEG30KBTA4/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOYG12KGCB/ASYG12KGTF
ASY**K
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOEG24KBCA3/ASEH07KMCG/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOEH12KJCA/ASEH12KJCAL
ASE**K
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOEH12KJCA/ASEH12KJCALB
ASE**K
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOEG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG14KBTA2/ASYG07KGTB/ASYG07KGTB
AOY**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOEG14KBCA2/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOYG14KBTA2/ASYH07KGTG/ASYH07KGTG
AOY**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
CL7000i 26 E / CL7000iU W 26 E
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 ES
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 EB
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 E
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 ES
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 EB
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 |