Filters · 3 active
Manufacturer:
CARRIER
DAIKIN
AIRCLASS
(2)
AIRWELL
(65)
ATLANTIC
(27)
AUX
(66)
BOSCH
(65)
BRYANT
(6)
Buderus
(20)
CIAT
(42)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
EQUATION
(5)
FUJI ELECTRIC
(150)
FUJITSU
(353)
Fujitsu Atlantic
(180)
GENERAL
(188)
GREE
(95)
GSS
(4)
HAIER
(451)
HEC
(5)
HEIWA
(5)
HISENSE
(213)
HITACHI
(116)
IVT
(1)
Inventor
(114)
KAYSUN
(66)
LG
(316)
MIDEA
(644)
MITSUBISHI ELECTRIC
(497)
Mitsubishi Heavy Industries
(284)
NORD
(40)
Nobu
(8)
PANASONIC
(197)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(147)
THERMOR
(43)
TOSHIBA
(193)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(9)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG140MV
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.31 | 4.37 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.31 | 4.37 | 13.40 | 9.52 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG71NV1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.23 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.23 | 12.10 | 9.52 | |||
|
RZAG100NV1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.31 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.31 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
5MWXM90A9 / FBA100A
5MWXM
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.22 | 4.21 | -15° | 8.70 | 6.46 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.19 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.19 | 12.10 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG35A / FCAG35B
RZAG
|
DAIKIN | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -20° | 3.50 | 3.30 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
RZAG125NV1 / FBA125A
RZAG
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FDA125A
RZAG
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.35 | 12.10 | 9.52 | |||
|
3MXM52A8 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -20° | 5.00 | 4.80 | |
|
RZAG71NV1 / FCAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.41 | 4.41 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FCAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.41 | 4.41 | -10° | 6.80 | 4.70 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.20 | 19.00 | 11.20 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
RZAG125NY1 / FBA125A
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FDA125A
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.35 | 12.10 | 9.52 | |||
|
RZAG71NV1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.33 | 22.00 | 12.10 | |||
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
3MXM52A9 / FTXM25R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25R / FTXM25R
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25A / FTXM25A
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP25N9 / FTXP25N9
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 |