Filters · 3 active
Manufacturer:
CIAT
DAIKIN
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(0)
BOSCH
(12)
BRYANT
(0)
Buderus
(6)
CARRIER
(5)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(17)
Fujitsu Atlantic
(9)
GENERAL
(21)
GREE
(6)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(2)
Inventor
(5)
KAYSUN
(1)
LG
(12)
MIDEA
(17)
MITSUBISHI ELECTRIC
(24)
Mitsubishi Heavy Industries
(24)
NORD
(0)
Nobu
(0)
PANASONIC
(24)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXZ25N / FTXZ25N
RXZ
|
DAIKIN | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.54 | 5.90 | 5.80 | -15° | 2.50 | 3.50 | |
|
RXM25A9 / FTXM25A
RXM
|
DAIKIN | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -20° | 2.50 | 2.40 | |
|
RXM25A9 / FTXM25A
RXM
|
DAIKIN | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -20° | 2.50 | 2.40 | |
|
RXZ35N / FTXZ35N
RXZ
|
DAIKIN | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.73 | 5.00 | -15° | 3.50 | 4.50 | |
|
RXM35A9 / FTXM35A
RXM
|
DAIKIN | Wall mounted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -20° | 3.50 | 2.50 | |
|
RXM35A9 / FTXM35A
RXM
|
DAIKIN | Wall mounted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -20° | 3.50 | 2.50 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MY1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MV
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 13.40 | 7.80 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.67 | 5.62 | 5.62 | 13.40 | 7.80 | ||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.67 | 5.62 | 5.62 | 13.40 | 7.80 | ||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.66 | 5.62 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.66 | 5.62 | 13.40 | 7.80 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.74 | 4.75 | 4.75 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.74 | 4.75 | 4.75 | 12.10 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.90 | 4.95 | 4.95 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.90 | 4.95 | 4.95 | 13.40 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.40 | 4.87 | 4.87 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.40 | 4.87 | 4.87 | 13.40 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 4.83 | 4.83 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 4.83 | 4.83 | 12.10 | 9.52 | ||
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXM25A / FTXM25A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.50 | 2.40 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RXM35A / FTXM35A
RXM
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -10° | 3.50 | 2.50 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.76 | 4.78 | 4.78 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.76 | 4.78 | 4.78 | 13.40 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
ARXM25A / ATXM25A
ARXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.30 | 5.15 | 5.00 | -10° | 2.50 | 2.40 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
ARXM35A / ATXM35A
ARXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.15 | 4.45 | -10° | 3.50 | 2.50 |