Filters · 3 active
Manufacturer:
FUJI ELECTRIC
Inventor
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(112)
EQUATION
(0)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(51)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(14)
IVT
(0)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(43)
Mitsubishi Heavy Industries
(64)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(29)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG36KBTB/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
ROG24KBTB/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
ROG18KBTB/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG45KRTA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROG45KBTB/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROG30KBTB/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
ROG30KATA/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
ROG54KRTA/RYG54KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
ROG36KATA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG18KATA/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
ROG22KATA/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
ROG45KQTA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
ROG45KATA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 |