Filters · 2 active
Manufacturer:
FUJI ELECTRIC
AIRCLASS
(1)
AIRWELL
(64)
ATLANTIC
(26)
AUX
(56)
BOSCH
(63)
BRYANT
(6)
Buderus
(19)
CARRIER
(94)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(381)
EQUATION
(4)
FUJITSU
(285)
Fujitsu Atlantic
(145)
GENERAL
(147)
GREE
(80)
GSS
(4)
HAIER
(430)
HEC
(5)
HEIWA
(4)
HISENSE
(171)
HITACHI
(76)
IVT
(1)
Inventor
(111)
KAYSUN
(65)
LG
(201)
MIDEA
(636)
MITSUBISHI ELECTRIC
(361)
Mitsubishi Heavy Industries
(180)
NORD
(38)
Nobu
(8)
PANASONIC
(133)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(103)
THERMOR
(43)
TOSHIBA
(124)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(7)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG22KBTB/RDG22KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
ROG36KBTB/RDG36KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG18KBTB/RDG18KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
ROG12KBTB/RDG12KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG30KBTA4/RSG07KMCC/RSG22KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
ROG24KBTB/RDG24KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
ROG18KBTB/RDG18KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG30KBTB/RDG30KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RDG30KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG22KBTB/RDG22KMLB
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
ROG18KBTB/RCG18KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
ROG24KBTB/RDG24KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
ROG36KBTB/RDG36KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG18KBTB/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
ROG12KVCA/RGG12KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG45KRTA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG45KBTB/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROH14KMCG/RSH14KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROH14KMCG/RSH14KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG30KBTB/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
ROG14KETA /RSG14KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA /RSG14KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KMCC/RSG14KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG07KMCC/RSG07KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA /RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KMCC/RSG07KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG09KMCC/RSG09KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROG09KETA /RSG09KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROG09KETA /RSG09KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROG09KETA/RSG09KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 |