Filters · 3 active
Manufacturer:
FUJITSU
HAIER
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(4)
AUX
(0)
BOSCH
(4)
BRYANT
(0)
Buderus
(4)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(42)
EQUATION
(0)
FUJI ELECTRIC
(16)
Fujitsu Atlantic
(21)
GENERAL
(19)
GREE
(3)
GSS
(0)
HEC
(0)
HEIWA
(1)
HISENSE
(1)
HITACHI
(16)
IVT
(0)
Inventor
(11)
KAYSUN
(3)
LG
(18)
MIDEA
(40)
MITSUBISHI ELECTRIC
(24)
Mitsubishi Heavy Industries
(19)
NORD
(0)
Nobu
(0)
PANASONIC
(15)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(14)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD71S2SM3FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.83 | 3.80 | 3.80 | -10° | 6.80 | 5.00 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AD140S2SM3FA/1U140S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | 13.40 | 11.00 | ||
|
AD140S2SM3FA/1U140S2SP1FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | 13.40 | 11.00 | ||
|
AC105S2SH1FA/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH2FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AD25S2SS1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
AD35S2SM9FA(H)/1U35S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 2.70 | |
|
AD71S2SM3FA/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AD71S2SS1FA/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 7.10 | 5.00 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
ADH125H1ERG/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
ADH125H1ERG/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
AC105S2SH1FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD50S2SS1FA(H)/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 5.00 | 4.30 | |
|
AD50S2SM3FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.00 | 4.50 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOEG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AC71S2SG2FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AS50XCAHRA/1U50KEFFRA-1
Expert electric heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.60 | 3.80 | 4.00 | -10° | 5.00 | 4.60 | |
|
AS50XCAHRA-MB/1U50KEFFRA-1
Expert electric heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.60 | 3.80 | 4.00 | -10° | 5.00 | 4.60 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
5U125S2SN1FA/AS71S2SF2FA-3/AS71S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
5U125S2SN1FA/AS71XCAHRA+AS71XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
5U125S2SN1FA/AS68PDAHRA+AS68PDAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
5U125S2SN1FA/AS71SEPHRA-MW+AS71SEPHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
AB35S2SA1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.72 | -10° | 3.50 | 3.00 | |
|
5U105S2SS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOYG45KBTB/ARXG45KMLA
ARX**K
|
FUJITSU | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KMLA
ARXG**K
|
FUJITSU | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KMLA
ARX**K
|
FUJITSU | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KMLA
ARX**K
|
FUJITSU | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AB71S2SA1FA/1U71S2SR3FA
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.72 | -10° | 6.90 | 5.00 | |
|
AS71S2SF1FA-MB3/1U71S2ST1FA
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.26 | -10° | 7.00 | 5.60 |