Filters · 3 active
Manufacturer:
FUJITSU
MIDEA
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(12)
AUX
(4)
BOSCH
(17)
BRYANT
(5)
Buderus
(8)
CARRIER
(37)
CIAT
(11)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(81)
EQUATION
(1)
FUJI ELECTRIC
(18)
Fujitsu Atlantic
(29)
GENERAL
(26)
GREE
(7)
GSS
(0)
HAIER
(234)
HEC
(2)
HEIWA
(1)
HISENSE
(44)
HITACHI
(37)
IVT
(1)
Inventor
(46)
KAYSUN
(19)
LG
(104)
MITSUBISHI ELECTRIC
(171)
Mitsubishi Heavy Industries
(85)
NORD
(28)
Nobu
(7)
PANASONIC
(33)
RIELLO
(14)
Rotenso
(4)
SAMSUNG
(77)
THERMOR
(12)
TOSHIBA
(96)
Viessmann
(5)
Vulcano
(6)
WESTPOINT
(0)
YORK
(12)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
AOEG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 14.10 | 11.30 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOEG18KLCA/ASEG18KLCA
ASE**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AG-12RD6N7H-O/AG-12RD6N7-I
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-Q(H)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-QRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-Q-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-QRD0W(GA)-GR/MTJ-48HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-Q(H)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOX630U-48HFN8-RRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-R(GA)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-R-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-RRD0W/MTJ-48HWFNX
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-R(H)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX430-18AFN8-QRD1GW/MSEPCU-18HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18HFN8-QRD1GW/MSEPCU-18HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18AFN8-QRD1GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18HFN8-QRD1GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOEG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
MOX630U-48HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.41 | -10° | 14.10 | 11.30 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.00 | -10° | 15.80 | 12.20 | |
|
MOX630U-48HFN8-RRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W/MUE-48HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MUE2-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(H)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MO-55N8-R-1/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-RRD0W/MUE-55HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 |