Filters · 3 active
Manufacturer:
Fujitsu Atlantic
KAYSUN
AIRCLASS
(0)
AIRWELL
(43)
ATLANTIC
(19)
AUX
(42)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(59)
CIAT
(32)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(239)
EQUATION
(4)
FUJI ELECTRIC
(68)
FUJITSU
(173)
GENERAL
(81)
GREE
(35)
GSS
(4)
HAIER
(349)
HEC
(5)
HEIWA
(3)
HISENSE
(126)
HITACHI
(43)
IVT
(0)
Inventor
(78)
LG
(156)
MIDEA
(361)
MITSUBISHI ELECTRIC
(148)
Mitsubishi Heavy Industries
(87)
NORD
(19)
Nobu
(6)
PANASONIC
(60)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(66)
THERMOR
(41)
TOSHIBA
(74)
Viessmann
(8)
Vulcano
(14)
WESTPOINT
(0)
YORK
(32)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
KUE-160 DTR14/KPD-160 DR15
Zen
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-140 DVR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPD-160 DR13
Zen
|
KAYSUN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
KUE-160 DTR13/KPD-160 DR14
Zen
|
KAYSUN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
KUE-52 DVR13/KPD-52 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
AOYG36KBTB/ARXG36KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
KUE-105 DVR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
KUE-105 DVR13/KPD-105V DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
KUE-125 DVR13/KPD-125 DR15
Zen
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
AOYG14KBTB/ARXG14KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
KUE-125 DVR13/KPD-125 DR13
Zen
|
KAYSUN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
KUE-125 DVR13/KPD-125 DR14
Zen
|
KAYSUN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
KUE-35 DVR13/KPD-35 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KPD-35V DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
KUE-105 DTR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
KUE-105 DTR13/KPD-105 DR15
Duct R32
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
KUE-140 DTR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
AOYG12KBTB/ARXG12KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG14KBTB/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
KUE-105 DVR13/KCIS-105 DR14
ZEN Cassette
|
KAYSUN | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
KUE-71 DVR13/KPD-71 DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPD-71V DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
KUE-140 DTR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
KUE-160 DTR14/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
KUE-160 DTR13/KCIS-160 DR14
Zen
|
KAYSUN | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
KUE-140 DTR13/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG45KBTB/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
KUE-140 DTR13/KPD-140 DR13
Zen
|
KAYSUN | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 |