Filters · 3 active
Manufacturer:
BOSCH
GENERAL
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(59)
BRYANT
(6)
Buderus
(28)
CARRIER
(106)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
DAIKIN
(305)
EQUATION
(5)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GREE
(71)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(270)
HITACHI
(118)
IVT
(3)
Inventor
(135)
KAYSUN
(62)
LG
(265)
MIDEA
(718)
MITSUBISHI ELECTRIC
(463)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(160)
THERMOR
(56)
TOSHIBA
(216)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(17)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AOHH14KGCG/ASHH14KGTG
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTH
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHG14KMCEN/ASHG14KMCEN
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOHG14KMCEN/ASHG14KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/AUXG18KRLB
AUH**K
|
GENERAL | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
AOHG14KBTB/AUXG14KVLA
AUH**K
|
GENERAL | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHH30KMTB/ASHH30KMTB
ASY**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOHG14KGCA/ASHG14KGTE
ASH**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
AOHG12KBTB/AUXG12KVLA
AUH**K
|
GENERAL | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
AOHG22KBTB/AUXG22KVLA
AUH**K
|
GENERAL | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.74 | -15° | 6.00 | 4.80 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AOHG14KGCB/ASHG14KGTF
ASH**K
|
GENERAL | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AOHG30KBTB/AUXG30KRLB
AUH**K
|
GENERAL | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTA4/ASHG07KMCC/ASHG22KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AOHG36KBTB/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG18KBTB/ARXG18KLLAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AOHG18KLTA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHG18KLCA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHH18KACB3/ASHH09KLTBL/ASHH09KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.20 | 3.80 | -15° | 5.00 | 4.30 | |
|
AOHH12KMCG/ASHH12KMCG
ASH**K
|
GENERAL | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.92 | -15° | 3.40 | 2.50 |