Filters · 3 active
Manufacturer:
BOSCH
GENERAL
AIRCLASS
(1)
AIRWELL
(26)
ATLANTIC
(8)
AUX
(28)
BRYANT
(1)
Buderus
(7)
CARRIER
(52)
CIAT
(21)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(441)
EQUATION
(1)
FUJI ELECTRIC
(59)
FUJITSU
(159)
Fujitsu Atlantic
(76)
GREE
(30)
GSS
(0)
HAIER
(243)
HEC
(0)
HEIWA
(0)
HISENSE
(65)
HITACHI
(88)
IVT
(1)
Inventor
(62)
KAYSUN
(45)
LG
(112)
MIDEA
(319)
MITSUBISHI ELECTRIC
(326)
Mitsubishi Heavy Industries
(332)
NORD
(15)
Nobu
(1)
PANASONIC
(111)
RIELLO
(22)
Rotenso
(8)
SAMSUNG
(69)
THERMOR
(12)
TOSHIBA
(138)
Viessmann
(12)
Vulcano
(5)
WESTPOINT
(4)
YORK
(22)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG30KBTA4/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHH30KMTB/ASHH30KMTB
ASY**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AOHG30KBTB/AUXG30KRLB
AUH**K
|
GENERAL | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTA4/ASHG07KMCC/ASHG22KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AOHG36KBTB/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG45KBTB/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG45KRTA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AOHG36KBTB/AUXG36KRLB
AUH**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG30KBTB/ARXG30KHTAP
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXG30KMLA
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOHH36KMTB/ASHH36KMTB
ASY**K
|
GENERAL | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
AOHG54KBTB/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG54KRTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG36KBTB/ARXG36KMLA
ARH**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
AOHG45KBTB/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
AOHG45KRTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOHG45LATT/AUHG45LRLA
AOHG**L
|
GENERAL | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOHG90LRLA/ARHG90LHTA
AOHG**L
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOHG54KRTA/ARXH54KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 |