Filters · 3 active
Manufacturer:
CARRIER
GENERAL
AIRCLASS
(1)
AIRWELL
(64)
ATLANTIC
(26)
AUX
(56)
BOSCH
(63)
BRYANT
(6)
Buderus
(19)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(381)
EQUATION
(4)
FUJI ELECTRIC
(115)
FUJITSU
(285)
Fujitsu Atlantic
(145)
GREE
(80)
GSS
(4)
HAIER
(430)
HEC
(5)
HEIWA
(4)
HISENSE
(171)
HITACHI
(76)
IVT
(1)
Inventor
(111)
KAYSUN
(65)
LG
(201)
MIDEA
(636)
MITSUBISHI ELECTRIC
(361)
Mitsubishi Heavy Industries
(180)
NORD
(38)
Nobu
(8)
PANASONIC
(133)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(103)
THERMOR
(43)
TOSHIBA
(124)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(7)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
42QSV030D8S*/38QUS030D8SX*
Ducted
|
CARRIER | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
42QSV012D8S*/38QUS012D8S-1
Ducted
|
CARRIER | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOHG12KBTB/ARXG12KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
38QUS018D8S2-2/42QSS009D8S*
Ducted
|
CARRIER | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
42QSV018D8S*/38QUS018D8S-1
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QZL036D8S*/38QUS036D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42QHE24D8SH*/38QHE24D8SH*
Wall mounted
|
CARRIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
42QSV036D8S*/38QUS036D8S*
Ducted
|
CARRIER | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AOHG30KBTA4/ASHG07KMCC/ASHG22KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
42QFD048D8S*/38QUS048D8T*
Floor Standing
|
CARRIER | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | 14.60 | 11.00 | ||
|
AOHG24KBTB/ARXG24KHTAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOHG36KBTB/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG18KBTB/ARXG18KLLAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
42QSS030D8S*/38QUS030D8S*
Ducted
|
CARRIER | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
AOHH18KACB3/ASHH09KLTBL/ASHH09KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.20 | 3.80 | -15° | 5.00 | 4.30 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42QZY018D8S*/38QUS018D8S*
Console
|
CARRIER | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
AOHG30KBTB/ARXG30KHTAP
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXG30KMLA
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
42QSV060D8S/38QUS060D8TX
Duct R32
|
CARRIER | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
42QSV048D8S/38QUS048D8TX
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8S
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
AOHG22KBTB/ARXG22KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KMLB
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
42QSS018D8S*/38QUS018D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
AOHG18KBTB/AUXG18KVLA
AUH**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
42QTD030D8S*/38QUS030D8S*
Cassette
|
CARRIER | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42QSS036D8S*/38QUS036D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
AOHG24KBTB/ARXG24KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
42QSS060D8S*/38QUS060D8T*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
42QSS042D8S*/38QUS042D8S*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42QTD012D8S*/38QUS012D8S*
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
42QTD012D8SN*/38QUS012D8S-1
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|