Filters · 2 active
Manufacturer:
GREE
Viessmann
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD71ZD1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | -10° | 7.10 | 4.70 | ||
|
GUD85ZD1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | -10° | 8.50 | 6.00 | ||
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
GWH09AKCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.73 | -10° | 2.70 | 3.00 | |
|
GWH12AKCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.49 | -10° | 3.53 | 3.20 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GWH24AVEXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 7.10 | 5.60 | |
|
GWH24AWEXF-K6DNA4A
MONOSPLITS
|
GREE | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 7.10 | 5.60 | |
|
GWH09AUCXB-K6DNA2D
MONOSPLITS
|
GREE | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.20 | 4.70 | 4.41 | -10° | 2.70 | 3.00 | |
|
GWH18AUDXF-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -10° | 5.30 | 4.20 | |
|
Vitoclima100-SPROIDHAA100MFP088/Vitoclima100-SPROOFAA100MFP088
Ducted
|
Viessmann | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
GWH18AUDXE-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
GWH18AVDXE-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.30 | 4.10 | |
|
GWH18AUDXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
GWH12AWCXD-K6DNA4D
MONOSPLITS
|
GREE | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.80 | 4.00 | -10° | 3.50 | 3.00 | |
|
GWH12AUCXD-K6DNA2E
MONOSPLITS
|
GREE | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.80 | 3.95 | -10° | 3.50 | 3.00 | |
|
GUD50T1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | -10° | 5.30 | 3.90 | ||
|
GWH09YCXB-K6DNA2C
MONOSPLITS
|
GREE | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 3.00 | |
|
GWH09YCXB-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 3.00 | |
|
GUD100PHS1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
GUD100PHS1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
GWH24AUDXF-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
GWH24AUDXF-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
GWH09AVCXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH18AUDXE-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.10 | -10° | 5.30 | 4.10 | |
|
GWH09ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.40 | -10° | 2.70 | 2.70 | |
|
GWH12AUCXD-K6DNA2F
MONOSPLITS
|
GREE | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.01 | -10° | 3.50 | 2.80 | |
|
Vitoclima100-SIDHAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
GUD71PHS1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.10 | -10° | 7.10 | 4.70 | ||
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
GUD100T1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | -10° | 10.50 | 7.00 | ||
|
GUD100T1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Cassette | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | -10° | 10.50 | 7.00 | ||
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ducted
|
Viessmann | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
GUD85T1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.30 | -10° | 8.50 | 6.00 | ||
|
GUD71T1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | -10° | 7.10 | 5.00 | ||
|
GWH12AUCXD-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
GUD35T1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | -10° | 3.50 | 3.10 | ||
|
GWH12AVCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
GUD35PS1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | -10° | 3.50 | 3.00 | ||
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
GWH09AUCXB-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AUCXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AWCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09ATCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 |