Filters · 3 active
Manufacturer:
BOSCH
HITACHI
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BRYANT
(0)
Buderus
(4)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(12)
Fujitsu Atlantic
(0)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(38)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(27)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(37)
THERMOR
(0)
TOSHIBA
(43)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 |