Filters · 3 active
Manufacturer:
DAIKIN
HITACHI
AIRCLASS
(0)
AIRWELL
(66)
ATLANTIC
(20)
AUX
(66)
BOSCH
(72)
BRYANT
(6)
Buderus
(18)
CARRIER
(118)
CIAT
(40)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
EQUATION
(3)
FUJI ELECTRIC
(150)
FUJITSU
(360)
Fujitsu Atlantic
(182)
GENERAL
(202)
GREE
(91)
GSS
(4)
HAIER
(441)
HEC
(5)
HEIWA
(4)
HISENSE
(261)
IVT
(1)
Inventor
(109)
KAYSUN
(64)
LG
(321)
MIDEA
(648)
MITSUBISHI ELECTRIC
(552)
Mitsubishi Heavy Industries
(352)
NORD
(40)
Nobu
(8)
PANASONIC
(254)
RIELLO
(43)
Rotenso
(8)
SAMSUNG
(167)
THERMOR
(43)
TOSHIBA
(265)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(3)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RZASG140MV
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.25 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.07 | 4.82 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.07 | 4.82 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.07 | 4.82 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.07 | 4.82 | 13.40 | 7.80 | |||
|
RXM50A9 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 3.95 | -20° | 5.00 | 4.50 | |
|
RXM50A9 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 3.95 | -20° | 5.00 | 4.50 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RXM50R / FTXM50R
RXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.71 | 4.00 | -20° | 5.00 | 4.60 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RZAG100NV1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
RZAG100NY1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RXM50A8 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.55 | 4.75 | 4.00 | -20° | 5.00 | 4.50 | |
|
RZAG71NV1 / FCAHG71H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.61 | 4.70 | -10° | 6.80 | 4.70 | |
|
RZAG71NV1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZAG100NV1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG100NV1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RAC-XJ50WHAE / RAK-XJ50RHAE
RAC-XJ-WHAE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 |