Filters · 3 active
Manufacturer:
Fujitsu Atlantic
HITACHI
AIRCLASS
(0)
AIRWELL
(43)
ATLANTIC
(19)
AUX
(42)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(59)
CIAT
(32)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(239)
EQUATION
(4)
FUJI ELECTRIC
(68)
FUJITSU
(173)
GENERAL
(81)
GREE
(35)
GSS
(4)
HAIER
(349)
HEC
(5)
HEIWA
(3)
HISENSE
(126)
IVT
(0)
Inventor
(78)
KAYSUN
(46)
LG
(156)
MIDEA
(361)
MITSUBISHI ELECTRIC
(148)
Mitsubishi Heavy Industries
(87)
NORD
(19)
Nobu
(6)
PANASONIC
(60)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(66)
THERMOR
(41)
TOSHIBA
(74)
Viessmann
(8)
Vulcano
(14)
WESTPOINT
(0)
YORK
(32)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
AOYG36KBTB/ARXG36KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG14KBTB/ARXG14KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG12KBTB/ARXG12KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
RPIH-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -15° | 8.50 | 6.50 | |
|
AOYG14KBTB/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RPIH-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 3.00 | -15° | 10.10 | 8.20 | |
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
RAS-5HNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG45KBTB/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
RPIH-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.28 | 3.70 | 3.29 | -10° | 12.10 | 9.50 | |
|
RAS-4HVRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
RAM-G110N5HAE / RAK-XJ50RHAE / RAK-XJ50RHAE
RAM-GNHE
|
HITACHI | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.94 | 3.50 | -15° | 10.00 | 8.70 | |
|
RAM-G110N5HCE / RAK-XJ50RHBE (G)/ RAK-XJ50RHBE(G)
RAM-GNHCE
|
HITACHI | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.94 | 3.50 | -15° | 10.00 | 8.70 | |
|
AOYG24KATA/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 |