Filters · 3 active
Manufacturer:
GENERAL
HITACHI
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(59)
BOSCH
(73)
BRYANT
(6)
Buderus
(28)
CARRIER
(106)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
DAIKIN
(305)
EQUATION
(5)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GREE
(71)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(270)
IVT
(3)
Inventor
(135)
KAYSUN
(62)
LG
(265)
MIDEA
(718)
MITSUBISHI ELECTRIC
(463)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(160)
THERMOR
(56)
TOSHIBA
(216)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(17)
YORK
(35)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
RAC-50NPE / RAK-50RPE1
RAC-NPE(D)
|
HITACHI | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.16 | 4.61 | 4.00 | -15° | 5.00 | 4.70 | |
|
RAC-50FXE / RAF-50RXE
RAC-FXE
|
HITACHI | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.80 | -20° | 5.00 | 4.61 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
RAM-G68N3HCE / RAK-XJ18QHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.00 | -10° | 6.80 | 5.90 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-90NYP5E / RAK-35RXE / RAK-50RXE
RAM-NYPE
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.90 | -15° | 8.50 | 7.10 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTG
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTH
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
RAM-Y53N3HAE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 3.99 | -10° | 5.30 | 5.60 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
RAC-50NPE / RAI-50RPE
RAC-NPE(D)
|
HITACHI | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.84 | 4.37 | 3.82 | -15° | 5.00 | 4.30 | |
|
AOHG14KMCEN/ASHG14KMCEN
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOHG14KMCEN/ASHG14KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
RAC-VJ60WHAE / RAK-V60RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.80 | -15° | 6.00 | 4.80 | |
|
RAC-VJ50WHAE / RAK-VJ50RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.60 | 3.85 | -15° | 5.00 | 4.35 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RAS-4HVRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAC-VJ70WHAE / RAK-VJ70RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 7.00 | 5.40 | |
|
RAM-G85N5HCE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
AOHG18KBTB/AUXG18KRLB
AUH**K
|
GENERAL | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
RAS-4HVNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-5HVRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
AOHG14KBTB/AUXG14KVLA
AUH**K
|
GENERAL | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHH30KMTB/ASHH30KMTB
ASY**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOHG14KGCA/ASHG14KGTE
ASH**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
AOHG12KBTB/AUXG12KVLA
AUH**K
|
GENERAL | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 |