Filters · 3 active
Manufacturer:
GENERAL
HITACHI
AIRCLASS
(0)
AIRWELL
(66)
ATLANTIC
(20)
AUX
(66)
BOSCH
(72)
BRYANT
(6)
Buderus
(18)
CARRIER
(118)
CIAT
(40)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(627)
EQUATION
(3)
FUJI ELECTRIC
(150)
FUJITSU
(360)
Fujitsu Atlantic
(182)
GREE
(91)
GSS
(4)
HAIER
(441)
HEC
(5)
HEIWA
(4)
HISENSE
(261)
IVT
(1)
Inventor
(109)
KAYSUN
(64)
LG
(321)
MIDEA
(648)
MITSUBISHI ELECTRIC
(552)
Mitsubishi Heavy Industries
(352)
NORD
(40)
Nobu
(8)
PANASONIC
(254)
RIELLO
(43)
Rotenso
(8)
SAMSUNG
(167)
THERMOR
(43)
TOSHIBA
(265)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(3)
YORK
(37)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.25 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
RAC-XJ50WHAE / RAK-XJ50RHAE
RAC-XJ-WHAE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAM-G70N4HAE / RAK-XJ35RHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.62 | 4.20 | -15° | 7.00 | 5.90 | |
|
RAC-50WXEN / RAK-50RXE
RAC-WXEN
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
AOHG09KBTB/ARXG09KLLAP
ARH**K
|
GENERAL | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
RAM-G55N3HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.76 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOHH18KMTG/ASHH18KMTGL
ASH**K
|
GENERAL | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
RAC-50NPE / RAK-50RPE1
RAC-NPE(D)
|
HITACHI | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.16 | 4.61 | 4.00 | -15° | 5.00 | 4.70 | |
|
RAC-50FXE / RAF-50RXE
RAC-FXE
|
HITACHI | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.80 | -20° | 5.00 | 4.61 | |
|
AOHG18KMTA/ASHG18KMTE
ASH**K
|
GENERAL | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-90NYP5E / RAK-35RXE / RAK-50RXE
RAM-NYPE
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.90 | -15° | 8.50 | 7.10 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
RAS-4HVRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.93 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 | |
|
AOHH14KGCG/ASHH14KGTG
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTH
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 |