Filters · 2 active
Manufacturer:
HAIER
HITACHI
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-4HRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
AS50S2SF1FA-WH/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-BH/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-LW/1U50S2SJ2FA-2
Flexis
|
HAIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-LW/1U50KEFFRA-1
Flexis
|
HAIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
AD71S2SM3FA/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.06 | 4.47 | 3.34 | -10° | 6.80 | 5.00 | |
|
2U40S3MEAFRA/AS25SBBHRA-MW/AS35SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25SBBHRA-MB/AS35SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-MW/AS35KBAHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-MB/AS35KBAHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-W/AS35KBAHRA-W
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-B/AS35KBAHRA-B
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MEAFRA-H/AS25SBBHRA-MW/AS35SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MEAFRA-H/AS25SBBHRA-MB/AS35SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25SBBHRA-MW/AS25SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25SBBHRA-MB/AS25SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-MW/AS25KBAHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-MB/AS25KBAHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-W/AS25KBAHRA-W
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40S3MEAFRA/AS25KBAHRA-B/AS25KBAHRA-B
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MEAFRA-H/AS25SBBHRA-MW/AS25SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MEAFRA-H/AS25SBBHRA-MB/AS25SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25SBBHRA-MW/AS25SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25SBBHRA-MW/AS35SBBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25SBBHRA-MB/AS25SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25SBBHRA-MB/AS35SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25PBBHRA-PA/AS25PBBHRA-PA
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25PBBHRA-PA/AS35PBBHRA-PA
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25RBBHRA-RBS/AS25RBBHRA-RBS
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25RBBHRA-RBS/AS35RBBHRA-RBS
Super Match Multi
|
HAIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
RAM-G36N2HCE / RAK-XJ18QHBE / RAK-XJ18QHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 3.60 | 3.50 | |
|
RAM-G43N2HCE / RAK-XJ18QHBE / RAK-XJ25RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 4.30 | 3.50 | |
|
RAM-E53N2HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
RAM-E53N3HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
AC71S2SG2FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.25 | 3.26 | -10° | 7.10 | 5.00 | |
|
AC50S2SG2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
AD35S2SM3FA/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 3.50 | 2.70 | |
|
RAC-60NPE / RAI-60RPE
RAC-NPE(D)
|
HITACHI | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.77 | 4.27 | 3.80 | -15° | 6.00 | 4.70 | |
|
AD140S2SM8FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
RAS-5HRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.89 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
RAS-5HVRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.26 | 3.98 | -20° | 11.90 | 11.93 |